USER INSTRUCTIONS
SCREW FEEDER FILLING
Loading the pellet screw feeder (coclea) is only neces-
sary if the boiler stove is new (and being switched on
for the rst time) or if the boiler stove had completely
run out of pellets.
To activate this loading, press the buttons
simultaneously, and the term “RI” is displayed.
The loading function ends automatically after 240” or if
you press the button.
IGNITION
With the boiler stove in stand-by, (after checking
that the grate is clean), press the
button and the
ignition procedure starts up.
The
term
“ON AC” (combustion starting) is dis-
played; after completing some control cycles and
when the pellets have actually ignited
the term
“ON
AC” is displayed (heating is being turned on).
This phase will last for a few minutes allowing the
ignition to be completed successfully and the boiler
stove's heat exchanger to be heated.
After a few minutes the boiler stove will move to the
heating phase, indicating
the term
“burn” and then,
during operation, it will display the delivery water
temperature set by the user and the power selected
by the automatic modulating system.
SWITCHING OFF
By pressing the button when the boiler stove is
ON, the switching o phase is started which in-
volves:
• Interruption to pellet supply
• Consumption of the last pellets in the grate, while
the ue fan stays on (typically for 10 min.)
• Cooling down of the boiler stove body maintaining
the pump in operation until the shutdown tempera-
ture is reached
• The term “OF” is displayed together with the num-
ber of minutes until switch-o .
During the switch-o phase, the boiler stove cannot
be switched on again; once the switch-o phase is
complete, the system will automatically go back to
standby.
AUTOMATIC OPERATION
It is necessary for the user to set the system deliv-
ery water temperature; this temperature must be as-
sessed in relation to the type and size of the system,
also considering the atmospheric temperature linked
to seasonal use.
The boiler stove, independently, regulates the power
according to the di erence between the set tem-
perature (set on the display) and the temperature
measured by the probe; when the desired temper-
ature is reached, the stove will operate at minimum
power on 1. You can increase the temperature
required by pressing the button or reduce it by
the pressing the
button.
The required temperature and the power that is
chosen automatically by the electronic modulating
system are displayed alternately.
ECONOMY FUNCTION
Function suitable for boiler stoves installed in small-
scale systems, or in mid-season when even mini-
mum power operation causes excessive heating.
This function, managed automatically, allows for
switching the boiler stove o once the set delivery
temperature is exceeded. The term “EC OF” will
be displayed indicating the minutes remaining to
switch-o .
When the delivery temperature falls below the set
value, the boiler stove switches back on automati-
cally. Request activation of this function, if required,
from the Technical Assistance Centre during initial
start-up.
REMOTE ACTIVATION FUNCTION (AUX
port)
By means of a special optional connection cable,
you can turn on/o the boiler stove using a remote
device such as a GSM remote telephone control, a
room thermostat, a command from a home auto-
mation system, or in any case from a device with
voltage free contact with the following logic:
Contact open = boiler stove OFF
Contact closed = boiler stove ON
Activation and deactivation occurs 10” after the last
command was transferred.
If the remote activation port is connected up, you
can still turn the boiler stove on/o using the control
panel; the boiler stove will always react in compli-
ance with the last order received, whether it is for
switching ON or switching OFF.
ROOM VENTILATION
To activate/deactivate the room temperature, press
the SET button for 3”; when “Air” is displayed, re-
lease the SET button, and using the +/- buttons set
to Air ON, if you want to activate ventilation or to Air
OFF, if you want to disable it.
Please note: the activation of ventilation is de-
pendent on this menu but also on a minimal water
temperature inside the boiler stove.
19


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for EK63-EdilKamin DORE160 H at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of EK63-EdilKamin DORE160 H in the language / languages: English as an attachment in your email.

The manual is 3.09 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of EK63-EdilKamin DORE160 H

EK63-EdilKamin DORE160 H Usermanual and installation guide - German - 28 pages

EK63-EdilKamin DORE160 H Usermanual and installation guide - French - 28 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info