4. Technical data
Power supply: 230 ~ 50 Hz
Motor rating in kW: 1.1
Compressor speed in rpm: 2850
Operating pressure in bar: 8
Pressure vessel volume in litre: 40
Theoretical intake rate in l/min.: 140
Sound power level L
WA
in dB: 92
Protection type: IP 20
Machine weight in kg: 23
5. Points to note when setting up the
compressor
n Examine the machine for signs of transit
damage. Report any damage immediately to the
company which delivered the compressor.
n The compressor should be set up near the
working consumer.
n Avoid long air lines and long supply lines
(extensions).
n Make sure the intake air is dry and dust-free.
n Do not set up the compressor in damp or wet
rooms.
n The compressor may only be used in suitable
rooms (with good ventilation and an ambient
temperature from +5°C to +40°C). There must be
no dust, acids, vapors, explosive gases or
inflammable gases in the room.
n The compressor is designed to be used in dry
rooms. It is prohibited to use the compressor in
areas where work is conducted with sprayed
water.
6. Assembly and starting
Important!
You must fully assemble the appliance before
using it for the first time.
6.1 Fitting the wheels (3)
Fit the supplied wheels as shown in Fig. 3.
6.2 Fitting the supporting foot (4)
Fit the supplied rubber stopper as shown in Fig. 4.
6.3 Voltage
The compressor is equipped with a mains cable with
shock-proof plug. This can be connected to any
230V ~ 50Hz shock-proof socket which is protected
by a 16 A fuse. Before you use the machine, make
sure that the mains voltage complies with the
specifications on the rating plate. Long supply
cables, extensions, cable reels etc. cause a drop in
voltage and can impede motor start-up. In the case
of low temperatures below +5°C, motor start-up is
jeopardized as a result of stiffness.
6.4 On/Off switch (8)
To switch on the compressor, pull out the knob (8).
To switch off the compressor, press the knob (8) in
again. (Fig. 2)
6.5 Adjusting the pressure: (Fig. 1)
n You can adjust the pressure on the pressure
gauge (6) using the pressure regulator (7).
n The set pressure can be taken from the quick-
lock coupling (5).
6.6 Setting the pressure switch
The pressure switch is set at the factory.
Switch-on pressure 6 bar
Switch-off pressure 8 bar
7. Replacing the power cable
If the power cable for this equipment is damaged, it
must be replaced by the manufacturer or its after-
sales service or similarly trained personnel to avoid
danger.
8. Cleaning and maintenance
Important!
Pull the power plug before doing any cleaning
and maintenance work on the appliance.
Important!
Wait until the compressor has completely cooled
down. Risk of burns!
Important!
Always depressurize the tank before carrying out
any cleaning and maintenance work.
8.1 Cleaning
n Keep the safety devices free of dirt and dust as
far as possible. Wipe the equipment with a clean
cloth or blow it with compressed air at low
pressure.
GB
13
Anleitung_TH_AC_200_40_OF_SPK1__ 08.08.13 09:19 Seite 13
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Einhell TH-AC 200-40 OF at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Einhell TH-AC 200-40 OF in the language / languages: English, Danish, Swedish, Norwegian as an attachment in your email.

The manual is 2,09 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Einhell TH-AC 200-40 OF

Einhell TH-AC 200-40 OF User Manual - German, Dutch, French, Italian, Portuguese, Spanish - 48 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info