Air capacity 500 m
3
/h
Absorbed humidity (30°C/80% RH) 1.0 l/h
Timer 24 h
Operating voltage 230 V ~ 50 Hz
Socket fusing 16 A
Nominal power consumption, cooling 1440 watts
Nominal current consumption, cooling 6.26 A
Nominal power consumption, heating 1440 watts
Nominal current consumption, heating 6.26 A
Compressor Rotary piston
Compressor starting current 24 A
Outdoor operating temperature 0 - +43 °C
Indoor operating temperature +16 - + 30°C
Fluid line Ø A 6,35 mm
Suction pipe Ø A 12,7 mm
Length of refrigerant line supplied 4 m
Length of refrigerant line, max. 10 m
Max. difference in height between indoor/outdoor
device 5 m
Refrigerant R 410 A
Refrigerant filling capacity 1400 g
Refrigerant refill quantity from 5 m 20 g/m
Sound pressure level
Inside ≤ 40 dB (A)
Outside ≤ 54 dB (A)
Dimension Inside 100,5 x 29 x 15 cm
Dimension Outside 84,8 x 54 x 32 cm
Weight Inside 16 kg
Weight Outside 40 kg
Note:
The specified capacities and performances are
based on the following conditions (EN 14511):
Cooling:
Air temperature at the inlet on the indoor device:
27°C for dry thermometer bulb (DB), 19°C for wet
thermometer bulb (WB). Outdoor air temperature:
35°C for dry thermometer bulb (DB), 24°C for wet
thermometer bulb (WB).
Heating:
Air temperature at the inlet on the indoor device:
20°C for dry thermometer bulb (DB), 15°C for wet
thermometer bulb (WB). Outdoor air temperature:
7°C for dry thermometer bulb (DB), 6°C for wet
thermometer bulb (WB).
Temperature ranges:
Cooling
Room temperature 16°C ~ 30°C
Outdoor temperature 18°C ~ 43°C
Heating
Room temperature 16°C ~ 30°C
Outdoor temperature 0°C ~ 24°C
Dehumidifying
Room temperature 16°C ~ 30°C
Outdoor temperature 18°C ~ 43°C
Notes:
1. For health reasons the room temperature should
be no more than 5 – 6°C below the outdoor
temperature in cooling mode.
2. The perfect performance of the system is
achieved within the temperature ranges shown in
the table.
3. If the air conditioning system is operated below
the temperature range shown above, protection
functions may be activated in certain
circumstances which will cause the device to
operate abnormally.
4. If the air conditioner is operated in a relative
humidity level of over 80%, condensation may be
deposited on the top of the system which will
then drip on to the floor. In this case set the
horizontal air flap to its maximum angle
(perpendicular to the floor) and set the FAN to
“HIGH”.
4. Intended use
The Split 900 Flat EQ C+H air-conditioning system is
only designed for air-conditioning privately used dry
rooms with a maximum room volume of 80 m
3
(Split
1200 Flat EQ C+H is suitable for a maximum room
volume of 110 m
3
). The room volume depends on the
local conditions. Large window areas, additional heat
sources (PC, television, people, etc.), poor wall
insulation, etc. serve to reduce this room volume.
The machine is to be used only for its prescribed
purpose. Any other use is deemed to be a case of
misuse. The user / operator and not the
manufacturer will be liable for any damage or injuries
of any kind caused as a result of this.
Please note that our equipment has not been
designed for use in commercial, trade or industrial
11
GB