724264
11
Zoom out
Zoom in
Previous page
1/24
Next page
Air capacity 500 m
3
/h
Absorbed humidity (30°C/80% RH) 1.0 l/h
Timer 24 h
Operating voltage 230 V ~ 50 Hz
Socket fusing 16 A
Nominal power consumption, cooling 1440 watts
Nominal current consumption, cooling 6.26 A
Nominal power consumption, heating 1440 watts
Nominal current consumption, heating 6.26 A
Compressor Rotary piston
Compressor starting current 24 A
Outdoor operating temperature 0 - +43 °C
Indoor operating temperature +16 - + 30°C
Fluid line Ø A 6,35 mm
Suction pipe Ø A 12,7 mm
Length of refrigerant line supplied 4 m
Length of refrigerant line, max. 10 m
Max. difference in height between indoor/outdoor
device 5 m
Refrigerant R 410 A
Refrigerant filling capacity 1400 g
Refrigerant refill quantity from 5 m 20 g/m
Sound pressure level
Inside ≤ 40 dB (A)
Outside ≤ 54 dB (A)
Dimension Inside 100,5 x 29 x 15 cm
Dimension Outside 84,8 x 54 x 32 cm
Weight Inside 16 kg
Weight Outside 40 kg
Note:
The specified capacities and performances are
based on the following conditions (EN 14511):
Cooling:
Air temperature at the inlet on the indoor device:
27°C for dry thermometer bulb (DB), 19°C for wet
thermometer bulb (WB). Outdoor air temperature:
35°C for dry thermometer bulb (DB), 24°C for wet
thermometer bulb (WB).
Heating:
Air temperature at the inlet on the indoor device:
20°C for dry thermometer bulb (DB), 15°C for wet
thermometer bulb (WB). Outdoor air temperature:
7°C for dry thermometer bulb (DB), 6°C for wet
thermometer bulb (WB).
Temperature ranges:
Cooling
Room temperature 16°C ~ 30°C
Outdoor temperature 18°C ~ 43°C
Heating
Room temperature 16°C ~ 30°C
Outdoor temperature 0°C ~ 24°C
Dehumidifying
Room temperature 16°C ~ 30°C
Outdoor temperature 18°C ~ 43°C
Notes:
1. For health reasons the room temperature should
be no more than 5 – 6°C below the outdoor
temperature in cooling mode.
2. The perfect performance of the system is
achieved within the temperature ranges shown in
the table.
3. If the air conditioning system is operated below
the temperature range shown above, protection
functions may be activated in certain
circumstances which will cause the device to
operate abnormally.
4. If the air conditioner is operated in a relative
humidity level of over 80%, condensation may be
deposited on the top of the system which will
then drip on to the floor. In this case set the
horizontal air flap to its maximum angle
(perpendicular to the floor) and set the FAN to
“HIGH”.
4. Intended use
The Split 900 Flat EQ C+H air-conditioning system is
only designed for air-conditioning privately used dry
rooms with a maximum room volume of 80 m
3
(Split
1200 Flat EQ C+H is suitable for a maximum room
volume of 110 m
3
). The room volume depends on the
local conditions. Large window areas, additional heat
sources (PC, television, people, etc.), poor wall
insulation, etc. serve to reduce this room volume.
The machine is to be used only for its prescribed
purpose. Any other use is deemed to be a case of
misuse. The user / operator and not the
manufacturer will be liable for any damage or injuries
of any kind caused as a result of this.
Please note that our equipment has not been
designed for use in commercial, trade or industrial
11
GB
Anleitung_SPLIT_900-1200_E+Q_C_H_GB:_ 18.01.2008 7:26 Uhr Seite 11
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Einhell Split 1200 FLAT EQ C-H at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Einhell Split 1200 FLAT EQ C-H in the language / languages: English as an attachment in your email.

The manual is 2,76 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Einhell Split 1200 FLAT EQ C-H

Einhell Split 1200 FLAT EQ C-H User Manual - German, French - 72 pages

Einhell Split 1200 FLAT EQ C-H User Manual - French - 24 pages

Einhell Split 1200 FLAT EQ C-H User Manual - Italian - 72 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info