134607
17
Zoom out
Zoom in
Previous page
1/24
Next page
The following pages are intended for
professional installers.
13. Important installation instructions
(Fig. 15)
Selecting the place to install the indoor device
The wall for installation must be strong and
capable of supporting the weight of the unit.
The air flow must never be blocked.
The cooled air should be capable of being
distributed to all parts of the room.
The maximum distance between the standard
indoor unit and outdoor unit is 4 m. The maximum
possible length of the refrigerant line is 10 m with
a maximum height difference of 5 m.
Mount on a solid wall to prevent vibrations.
Avoid direct sunlight.
Take into account a slight condensate run-off.
Selecting the place to install the outdoor device
The wall for installation must be strong and
capable of supporting the weight of the unit.
The device must not be exposed to strong gusts of
wind.
Make sure that the device is well ventilated and
kept free of dust. Avoid direct exposure to rain and
sunlight.
Make sure that the operational noises and air
emissions do not cause a nuisance for
neighbours.
Install on a firm base, avoiding excessive noise or
vibrations.
Avoid locations where combustible gas or leakage
can be emitted.
Fix the deviceʼs installation feet with care if the
device is to be installed well above them.
Important
Do not hesitate to contact our service partners. They
will be able to give you a speedy response to all your
questions so that your system can be installed
correctly.
14. Installation accessories
Please check that all the installation accessories
have been supplied prior to carrying out the
installation work.
1 mounting plate for the indoor device
1 infrared remote control
2 batteries (type AAA, 1.5 V)
1 condensed water hose (L = 2 m)
2x sealing compound
1 wall hole cap
2 roll of plastic wrapping tape
1 set of refrigerant lines (L = 4 m)
1 pipe insulation (Ø 35 x 500 mm)
8 screws ST 3.9x25
8 wall plugs
1 wall passage hole
15. Installation instructions:
Check that the actual mains voltage is the same
as the mains voltage specified on the rating
plate.
Important. Make sure that there are no electric
cables or other installations (for example water
pipes) near the drill holes.
Earth the outdoor device in accordance with
current regulations.
The device must have separate protection
against short-circuits.
Have all work of electrical installation performed
by an electrician.
Ask a service partner or specialist cooling
system firm to undertake all work of installing the
cooling system.
Incorrect installation can lead to injury or damage
to property.
Always wear ear muffs, goggles and work gloves
when performing work of installation.
Notes on electrical connection!
All electrical connection work must be performed by
a qualified electrician authorized to do so such work
by the applicable electricity supply company. The
system must have separate protection against short-
circuits. Select a suitably large cable cross-section.
The yellow/green wire is to be used as a protective
conductor only and under no circumstances as a
voltage carrying conductor. The fixed electrical
connection of the device must be capable of being
isolated from the mains power supply by a device
with an isolating distance of at least 3mm (e.g.
circuit-breaker). Connect the electrical connections of
the indoor and outdoor devices together first and
then connect to the mains power supply. Check first
that the entire system is voltage-free. Secure the
system from being switched on again.
GB
17
Anleitung_SKA_5003_C_H_GB:_ 28.11.2007 16:24 Uhr Seite 17
17


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Einhell ska 5003 c h at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Einhell ska 5003 c h in the language / languages: English as an attachment in your email.

The manual is 2,42 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Einhell ska 5003 c h

Einhell ska 5003 c h User Manual - German - 28 pages

Einhell ska 5003 c h User Manual - Dutch - 28 pages

Einhell ska 5003 c h User Manual - French - 28 pages

Einhell ska 5003 c h User Manual - Italian - 28 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info