724236
24
Zoom out
Zoom in
Previous page
1/28
Next page
6. Fig. 37-39: Now remove the cover on the bottom
valve using a 19 mm open-ended spanner. Open
the valve by turning it counter-clockwise as far as
it will go using a 5 mm Allen key. The valve is
now open. If the valve is not opened fully, the
system may malfunction and suffer damage.
Screw the cover back on to the bottom valve and
tighten it well to ensure that it is properly sealed.
Important! The conical ring on the valve has an
important sealing function together with the sealing
seat in the caps. Ensure that you do not damage the
cone and that you keep the cap free of dirt and dust.
7. After completing steps 1 – 6, check that all the
connections are sealed correctly using leak
detection spray or soap suds. If any bubbles
form, the system has a leak and the screw
connectors must be retightened using an open-
ended spanner.
8. Start the equipment so that the operating
pressures build up inside it. Check all the
connectors again for signs of leaks
a) during cooling mode
b) in heating mode.
If any bubbles form, the system has a leak and
the screw connectors must be retightened using
an open-ended spanner.
9.
Secure the connection protective cover back into
position.
4. Electrical connection of indoor and outdoor
devices (Fig. 40/41)
Follow all instructions and notes on electrical
connection.
1. Unscrew the connection protective cover (A).
2. Connect the exposed end of the connection
cable (I) which leads from the indoor device to
the outdoor device to the plug-coupling system
on the outdoor device (C). Connect the PE-wire
according the drawing.
3. Fasten the connector cable to the outdoor device
using the cable clamps (K).
4. Screw the connection guard back (A) on the
outdoor device.
Fasten the complete package of lines, with the
protective tape wrapped around them, to the outside
wall using the supplied plastic clamps.
5. Remote control holder
Before you mount the holder, check that the remote
control can be received by the indoor device from the
planned location for the holder. Do not select a
position in direct sunlight or in the vicinity of any
sources of heat.
Check that the + and – terminals on the batteries
are positioned correctly in the remote control.
Fasten the remote control holder to the wall with
dowels and screws.
15. Ordering replacement parts
Please quote the following data when ordering
replacement parts:
Type of machine
Article number of the machine
Identification number of the machine
Replacement part number of the part required
For our latest prices and information please go to
www.isc-gmbh.info
GB
24
Anleitung_SKA_2503_E+Q_C_H_GB:_ 10.12.2008 11:28 Uhr Seite 24
24


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Einhell SKA 3503 EQ C-H at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Einhell SKA 3503 EQ C-H in the language / languages: English as an attachment in your email.

The manual is 5,01 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Einhell SKA 3503 EQ C-H

Einhell SKA 3503 EQ C-H User Manual - German - 32 pages

Einhell SKA 3503 EQ C-H User Manual - Dutch - 32 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info