724236
20
Zoom out
Zoom in
Previous page
1/28
Next page
conductor. The fixed electrical connection of the
device must be capable of being isolated from the
mains power supply by a device with an isolating
distance of at least 3 mm (e.g. circuit-breaker).
Connect the electrical connections of the indoor and
outdoor devices together first and then connect to
the mains power supply. Check first that the entire
system is voltage-free. Secure the system from being
switched on again.
A. Selecting the place of installation
Indoor device
1. The openings for the inlet and outlet air must
never be covered, otherwise the air will not be
distributed throughout the entire room.
2. Install the indoor device in a location which
ensures that the distance through the wall to the
outdoor device is as short as possible.
3. Make sure that the drainage hose does not have
any kinks or upward inclines when you connect it
with the outside.
4. Do not select a location adjacent to a source of
heat, high humidity or inflammable gas.
5. Select a location which is firm enough for
installation so that the device is not subjected to
vibrations.
6. Check that the device has been installed
correctly and exactly.
7. Make sure that there is sufficient space available
for later repair and service work.
8. The device should be installed at a distance of at
least 1 m from all other electrical devices and
installations, e.g. TV, radio, computer, etc.
9. Select a location for the device which is easily
accessible so that the filter can be cleaned or
replaced without difficulty.
10. The maximum distance between the standard
indoor unit and outdoor unit is 4 m. The
maximum possible length of the refrigerant line is
10 m with a maximum height difference of 5 m.
11. Avoid direct sunlight.
Outdoor device
1. Select a location which avoids causing a
nuisance to neighbours from noise and air
emissions from device.
2. Select a location which is sufficiently well
ventilated.
3. Never cover the air inlets and outlets.
4. The location must be sufficiently firm for
installation and the prevention of vibrations.
5. There must be no risk presented by combustible
gas or gas escaping as a result of corrosion.
6. Check that the device is installed in accordance
with regulations.
7. It should be installed at least 20 cm above the
expected snow line. Snow must not be allowed
to get into the outdoor unit.
8. The wall for installation must be strong and
capable of supporting the weight of the unit.
9. The device must not be exposed to strong gusts
of wind.
10. Make sure that the device is well ventilated and
kept free of dust. Avoid direct exposure to rain
and sunlight.
11. Install on a firm base, avoiding excessive noise
or vibrations.
Important:
The following could cause malfunctions.
Check with your service company in order to
prevent possible malfunctions at a later date.
The following locations should be avoided for
installation:
A location where oil (machine oil) is stored.
A location where there is a high salt content.
A location with numerous sulphurous sources,
e.g. spa zones.
A location where radio transmitters or amplifier
aerials, welding equipment or medical equipment
are in use.
A location where the outdoor device is exposed
to direct sunlight. If necessary the device must
be protected with a sun-shade. Such a sun-
shade must not interfere with the air flow,
however.
A location in the vicinity of heat or steam
generators.
A location which is heavily exposed to dust.
A location to which the general public have
access.
A location with any other unusual characteristics.
Important!
The direction in which the air is blown should
correspond with the prevailing direction of the
wind.
Never install in locations exposed to aggressive
air.
Comply with all specified minimum distances
(see Important notes on installation).
The indoor and outdoor devices may only be
installed if they are in a horizontal position
measured using a spirit level. Check this after
you have completed the installation work.
Do not kink or compressed the refrigerant lines.
All the refrigerant lines, including connectors and
valves must be fitted with diffusion-resistant heat
GB
20
Anleitung_SKA_2503_E+Q_C_H_GB:_ 10.12.2008 11:28 Uhr Seite 20
20


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Einhell SKA 3503 EQ C-H at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Einhell SKA 3503 EQ C-H in the language / languages: English as an attachment in your email.

The manual is 5,01 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Einhell SKA 3503 EQ C-H

Einhell SKA 3503 EQ C-H User Manual - German - 32 pages

Einhell SKA 3503 EQ C-H User Manual - Dutch - 32 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info