12
Check the mains lead at regular intervals for
signs of defects or damage. A damaged mains
lead may only be replaced by an electrician or
ISC GmbH in compliance with the relevant
regulations.
CAUTION!
Read all safety regulations and instructions.
Any errors made in following the safety regulations
and instructions may result in an electric shock, fire
and/or serious injury.
Keep all safety regulations and instructions in a
safe place for future use.
Packaging:
The unit is supplied in packaging to prevent it from
being damaged in transit. The raw materials in this
packaging can be reused or recycled.
Tips on saving energy
Only use the air conditioner when you really need to.
Do not select too high a temperature for heating or
too low a temperature for cooling. Select the “Sleep”
function during the night.
Close all windows, doors and Venetian blinds in
order to reduce incoming sunlight as far as possible.
Principle of operation for cooling
Heat is extracted from the air in the room by the air
heat-exchanger (evaporator) in which the coolant
circulates. This air is conveyed to the outside air
heat-exchanger (condenser).
This gives off heat to the outdoor air. Electrical
energy is required for this. In certain circumstances
condensation may form on the evaporator on the
indoor unit, which will be removed by the
condensation hose.
2. Items supplied
SKA 2503 EQ C+H
1 indoor device (box 1, art. no. 23.654.14)
1 outdoor device (box 2, art. no. 23.654.15)
1 set of installation accessories (for details, see page
19)
SKA 3503 EQ C+H
1 indoor device (box 1, art. no. 23.654.16)
1 outdoor device (box 2, art. no. 23.654.17)
1 set of installation accessories (for details, see page
19)
3. Technical data
SKA 2503 EQ C+H
Cooling capacity 2600 watts
Heating capacity 2800 watts
Energy efficiency B (EER 3.09/COP 3.33)
Air capacity 410 m
3
/h
Absorbed humidity 1.0 l/h
Timer 24 h
Operating voltage 220 - 240 V ~ 50 Hz
Socket fusing 16 A
Nominal power consumption, cooling 840 watts
Nominal current consumption, cooling 3.7 A
Nominal power consumption, heating 830 watts
Nominal current consumption, heating 3.7 A
Compressor Rotary piston
Compressor starting current 22 A
Outdoor temperature, cooling operation °C
+18 - +43 (DB)
Outdoor temperature, heating operation °C
-7 - + 24 (DB)
Fluid line Ø A 6.35 mm
Suction pipe Ø A 9.53 mm
Length of refrigerant line supplied 4 m
Length of refrigerant line, max. 10 m
Max. difference in height between indoor/outdoor
device 5 m
Refrigerant R 410 A
Refrigerant filling capacity 730 g
Refrigerant refill quantity from 5 m 20 g/m
Sound pressure level
Inside ≤ 39 dB (A)
Outside ≤ 53 dB (A)
Dimension Inside 79 x 27,5 x 19 cm
Dimension Outside 78 x 54 x 25 cm
Weight Inside 8,5 kg
Weight Outside 28 kg
SKA 3503 EQ C+H
Cooling capacity 3300 watts
Heating capacity 3600 watts
Energy efficiency B (EER 3.14/COP 3.42)
Air capacity 620 m
3
/h
Absorbed humidity 1.2 l/h
Timer 24 h
Operating voltage 220 - 240 V ~ 50 Hz
Anleitung_SKA_2503_E+Q_C_H_GB:_ 10.12.2008 11:28 Uhr Seite 12
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Einhell SKA 3503 EQ C-H at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Einhell SKA 3503 EQ C-H in the language / languages: English as an attachment in your email.

The manual is 5,01 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Einhell SKA 3503 EQ C-H

Einhell SKA 3503 EQ C-H User Manual - German - 32 pages

Einhell SKA 3503 EQ C-H User Manual - Dutch - 32 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info