Operating Instructions for the
Indoor and Outdoor Device
Split-system Air Conditioner
Important note:
This high-quality product will only offer
optimum service if installed correctly and in
the right place, and is put into operation for
the first time by a suitably competent person.
Avoid malfunctions by seeking competent
advice from an expert with regards to the
location, installation and starting up of the
system.
We shall accept no liability for malfunctions
or inadequate cooling performance resulting
from the improper handling of the product.
Only a suitably qualified firm is permitted to
undertake any work of making the electrical
and cooling system connections and putting
the system into operation for the first time.
If the system is to be moved to another
location or disposed of, only a suitably
qualified electrician’s/cooling system firm is
permitted to undertake any work of
disassembly or disposal.
SKA 3500 C+H
Art.-Nr.: 23.653.22 I.-Nr. 01012
Anleitung SKA 3500 C+H_GB 20.01.2006 9:14 Uhr Seite 1
2
1. Safety instructions
Read the safety instructions before you start to
use the device.
These points set out extremely important
precautionary measures that you must comply
with.
Keep the Operating Instructions in a safe place
once you have read them.
Check that the drainage line is correctly
connected. If not, water will escape.
Warning!
Do not extend the cable and never use multiple
plugs. A poor electrical connection, poor
insulation or voltage which is higher than
permitted can cause fire.
Remove all dirt from the power plug and plug
it in firmly. Soiled plugs can cause fire or an
electric shock.
Warning!
Never pull out the plug while the device is in use.
Never permit cool air to be blown directly at you
for any lengthy period of time.
In the event of any abnormalities (e.g. smell of
burning), immediately switch off the device and
pull the plug. Contact your service partner.
Never poke fingers or sticks in the air inlet and
outlet vents.
Never attempt to repair the air conditioner
yourself. Always contact your service partner if it
requires repair.
Never pull the plug out by pulling on the cable.
Hold the plug firmly and pull it out of the plug
socket, otherwise there is a risk of damaging the
cable.
Always switch off the device and pull the plug
before you start to clean it.
Never actuate any switches with wet hands.
Never clean the air conditioner with water.
Never place any plants or animals under a
location to which cool air flows as this could have
an undesirable affect on them.
Never use combustible cleaning agents as these
could cause a fire or deformation.
If the air conditioner is to be used in conjunction
with other heaters, the air should be refreshed
periodically, otherwise there is a risk of lack of
oxygen.
Never use the device for any other purpose than
the intended use. Never place food, precision
instruments, plants, animals, paint, etc. on the
device.
Never hold any burning objects close to the
device if they could be directly affected by the
emitted air.
Always pull out the power plug if the device is not
going to be used for any lengthy period of time.
Collections of dust can cause fire.
Never step onto the outdoor device and never
place anything on it.
Never use an unsteady or rusty base.
Never allow the device to run for too long with the
doors or windows open, or if the humidity is very
high. If the air conditioner runs for a long time in
cooling mode and the humidity is high (over
80%), condensed water may drip out of the
device.
Never stand on an unsteady base when you
remove the device from the holder on the wall.
Check that the condensation water can run off
unhindered. Water damage can result if the
condensation water cannot run off properly.
Never touch any metal parts on the indoor device
when removing the air filter. You may injure
yourself.
Never install the device in a room in which
combustible gases can be emitted. Emitted gases
may collect and cause an explosion.
Always switch off the device and pull out the
power plug during a storm. Electrical parts may
get damaged.
Earthing connection!
The power cable (plug) comes with an earthing
wire. Do not, therefore, change the plug.
For electrical safety purposes we recommend
that you install an earth-leakage circuit-breaker.
Have all electrical installation work performed by
a qualified electrician.
Ask a service partner or specialist cooling system
firm to undertake all work of cooling system-
related installation.
Incorrect installation may cause injury or damage
to the device.
Anleitung SKA 3500 C+H_GB 20.01.2006 9:14 Uhr Seite 2
3
2. Technical data
Cooling capacity 3,500 watts
Heating capacity 3,800 watts
Energy efficiency B (EER 3.02/COP 3.42)
Air capacity 520 m
3
/h
Absorbed humidity 1.3 l/h
Timer 24 h
Operating voltage 230 V ~ 50 Hz
Nominal power consumption, cooling 1,320 watts
Nominal power consumption, heating 1,360 watts
Compressor Rotary piston
Outdoor temperature, cooling operation °C +21 - +43 (DB)
Outdoor temperature, heating operation °C +7 - +24 (DB)
Fluid line Ø A 6 mm
Suction pipe Ø A 12 mm
Length of refrigerant line supplied 4 m
Length of refrigerant line, max. 15 m
Max. difference in height between indoor/outdoor device 5 m
Refrigerant R 407 C
Refrigerant filling capacity 900 g
Refrigerant refill quantity from 5 m 20 g/m
Sound pressure level
Inside ≤ 40 dB (A)
Outside ≤ 55 dB (A)
Dimensions
Inside 79 x 27,5 x 18 cm
Outside 83 x 54,5 x 25,5 cm
Weight
Inside 10 kg
Outside 36 kg
Note:
The specified capacities and performances are based on the following conditions (ISO 5151):
Cooling:
Air temperature at the inlet on the indoor device: 27°C for dry thermometer bulb (DB), 19°C for wet
thermometer bulb (WB). Outdoor air temperature: 35°C for dry thermometer bulb (DB), 24°C for wet
thermometer bulb (WB).
Heating:
Air temperature at the inlet on the indoor device: 20°C for dry thermometer bulb (DB), 15°C for wet
thermometer bulb (WB). Outdoor air temperature: 7°C for dry thermometer bulb (DB), 6°C for wet thermometer
bulb (WB).
Anleitung SKA 3500 C+H_GB 20.01.2006 9:14 Uhr Seite 3
4
1 Front panel
2 Air outlet vent
3 Air filter
4 Left / right slats
5 Controller
6 Emergency switch
7 Remote control
8 Color display
9 Top / bottom slats
3. Description of parts
Indoor device
1
3
7
8
5
4
6
2
9
Anleitung SKA 3500 C+H_GB 20.01.2006 9:14 Uhr Seite 4
5
Outdoor device
1 At the rear: air inlet
2 Hose package
3 Water drainage hose
4 Air vent
5 Water drainage hole
1
2
3
4
5
Anleitung SKA 3500 C+H_GB 20.01.2006 9:14 Uhr Seite 5
6
1 Signal output window
2 Function display
3 On/Off switch
4 Function switch (mode
switch)
4a Automatic function
4b Cool
4c Dehumidify (Dry)
4d Heat
5 Switch for air circulation
velocity
6 Sleep selection key
7 Timer-on key
8 Hours selection switch,
minute setting, time setting
9 Clock setting
10 Temperature adjustment
key
11 Key for setting the air flow
angle
12 Full blast key
13 Timer-off key
14 Reset key
15 Battery cover opener
4. Remote control:
1
2
3
4
5
10
4a
4b
4c
4d
11
12
13
14
9
15
8
7
6
Anleitung SKA 3500 C+H_GB 20.01.2006 9:14 Uhr Seite 6
7
Preparing to use the remote control for the first time and setting the current time.
1
2
3
4
5
Open the rear cover and insert the batteries.
Press the reset key with a pointed
object.
Always press the reset key once after every
battery change.
Do not forget to do so, otherwise normal
operation will not be possible.
Press the clock setting key with a
pointed object.
Press the hours/minutes with
the time setting key and set
the right time.
Press the hours key and set
the hours.
Press the minutes key and
set the minutes.
(Please take AM=24.00-
12.00 or PM=12.00-24.00
into account!)
Now press the clock setting key again and
replace the cover on the back.
Make sure that the + and –
terminals are positioned correctly
when you load the batteries.
Anleitung SKA 3500 C+H_GB 20.01.2006 9:14 Uhr Seite 7
8
Preparation for use of the remote control
- The radio signal has a range of approx. 6 m.
- When the ON/OFF button is pressed, the indoor device will
emit an audio signal once or twice to indicate that the device
has received the signal.
- If you do not hear a signal, press again.
- Handle the remote control with care and, in order to avoid
malfunctions, never drop it or leave it in a damp location.
Attach the remote control to the wall in such a way that the
receiver on the indoor device can receive the remote control
signal effectively.
Changing the batteries!
- If the signal on the remote control becomes weak or the
indicator on the remote control becomes difficult to read,
replace the batteries immediately.
- It is important that the + and – terminals on the batteries are
correctly positioned in the remote control.
- Both batteries should always be new and of the same make.
Remote control fails to work (emergency operation)
If the remote control fails to work (empty batteries or malfunction),
use the emergency switch.
When you press the key, the function changes in the following
sequence:
- Cooling - Stop.
For the first 30 minutes the temperature adjustment does not yet
function.
Function Cooling
Set temperature 24°C
Air speed Medium
Air flow slats Automatic
The function in question is indicated on the indoor device.
Emergency
switch
Anleitung SKA 3500 C+H_GB 20.01.2006 9:14 Uhr Seite 8
9
To stop,
Press the ON/OFF KEY
15 minutes after switching off, you may feel that it
is possibly a little too hot. To reduce the
temperature a little, press the key (too hot).
Each press of the key will reduce the temperature
by 1° C.
If it is too cold, increase the temperature with the
key (too cool).
Each press of the key will increase the
temperature by 1° C.
To start
Press the ON/OFF KEY
If automatic function is indicated, the air
conditioner switches to a comfortable room
temperature.
“I feel ...” automatic function
A light press of the automatic function “I feel” can produce a comfortable room
temperature.
LCD display for the indoor
Low/high indicator
Anleitung SKA 3500 C+H_GB 20.01.2006 9:14 Uhr Seite 9
10
If the automatic function is not shown, press key “4” as often as is required for the automatic function (4a) to
be shown.
Each time the key is pressed the sequence changes: Automatic (4a) - Cool (4b) - Dehumidify (Dry) (4c) - Heat
(4d).
Structure of the automatic function
Operation functions.
When the automatic function is started, the mode of operation for the room temperature adjusts to the
corresponding function such as cool, dehumidify, etc. If operation is stopped for 2 hours, it begins again with
the same function setting that it had before it stopped. Once the corresponding function has become set, it will
no longer be affected by the room temperature, even if it changes. If you do not wish to use this function,
press the key in order to set one of the following functions.
Automatic function once the room temperature has been checked.
Room temperature at start Function Set-point
temperature
Above +25°C Cool approx. 24°C
+21-25°C Ventilate / Dehumidify ———-
Below 21°C Heat approx. 24°C
Note:
The heat function can be used for outdoor temperatures down to +7°C. Heating is not possible if the outdoor
temperature is any lower.
4
4a
4b
4c
4d
Anleitung SKA 3500 C+H_GB 20.01.2006 9:14 Uhr Seite 10
11
Selecting the mode function (cool (4b), dehumidify (4c), heat (4d)). Select Mode in order
to finely adjust the room temperature or air flow.
Important!
If the ambient temperature is too high the
cooling system works at maximum
capacity.
To select cool, dehumidify or heat:
1 Press the ON/OFF key.
2 Press to select the
corresponding function.
Every time you press the key the function
changes in the following sequence: Automatic -
Cool - Dehumidify – Heat
Heat function:
Select the heat function with key 4.
The heat function can be used at any time as
long as the outdoor temperature is above
approx. +7°C. The maximum room temperature
to be reached depends on the outdoor
temperature and the nature of the particular
building.
Note: If during operation the room temperature
is more than 2°C above (cool) or less than 2°C
below (heat) the set-point temperature, the set-
point temperature on the air conditioner cannot
be changed. As soon as the temperature
difference between the room temperature and
the predefined set-point temperature is less
than 2°C again, it will be possible to change the
set-point temperature on the air conditioner
again.
The lower the outdoor temperature, the lower
the room temperature that can be achieved with
the heater function.
If you wish to switch off the device:
Press the ON/OFF key.
Once the device has been set for the first time,
all you have to do to return to the previous
function is press the ON key.
4
4b
4c
4d
4a
Anleitung SKA 3500 C+H_GB 20.01.2006 9:14 Uhr Seite 11
12
Changing the temperature
Press the “too hot” key to reduce the temperature. Each press
of the key reduces the set temperature by 1°C.
Press the “too cool” key to increase the temperature. Each
press the key increases the temperature by 1°C.
The system can become overloaded if the air conditioner draws
too much heat from the air. The fan on the outdoor device stops
automatically, thanks to the microprocessor controller, to protect
the air conditioner. If the fan on the outdoor device stops, the
outdoor device will indicate frost.
This is not a fault or malfunction.
Dehumidifying mode
If the temperature is set to the automatic function, this function cannot be changed.
Selecting the function (cool, dehumidify).
Monitoring during operation:
1. In order to increase the cooling effect, close the windows and lower the roller blinds or reduce incoming
sunlight.
2. Lower the venetian blinds in order to reduce incoming sunlight.
3. Install the outdoor device in a suitable place away from direct sunlight, where it will save energy.
Dehumidifying
70% air humidity is the upper limit with which the human
body feels comfortable.
If it is too warm for the human body this means the water
content is too high, i.e. humidity is too high. Humidity has a
certain relationship to temperature. As a general rule, the
following applies: 60-70% for the summer and 50-70% for
the winter.
Anleitung SKA 3500 C+H_GB 20.01.2006 9:14 Uhr Seite 12
13
Adjusting the air velocity and air flow
Select the air flow and air circulation with which you feel most comfortable.
Press the key to adjust the air
velocity. Each press of the key
changes the air velocity as follows:
Low, moderate, high, automatic.
Select a high setting if you
wish to cool the entire room.
Select the sleep function when
you want to sleep and wish to
reduce the noise level while
sleeping.
Press the key to adjust the
direction of the air up/down. Each
press of the key changes the
direction.
Anleitung SKA 3500 C+H_GB 20.01.2006 9:14 Uhr Seite 13
14
Recommended range for the air flow up/down. Adjust with the automatic
key. Select cool, heat or dehumidify.
Important:
- In the dehumidify and cool function the air is blown downwards for 1 hour
(Item 4 - 5). Then the device switches to horizontal air flow in order to
prevent dripping.
- Adjust the up/down direction using the remote control. Never attempt to
adjust the height by hand.
- If the blown-out air temperature is too cold in heat mode, the air will be
blown out virtually horizontally. Adjust to the desired flow direction and
velocity.
Adjusting the air velocity and direction of flow
Automatic air flow
Press the key, change the air flow to automatic and the optimum slat position will be selected for efficient
effect.
Cool + Dehumidify
In cool and dehumidify the
air flows out horizontally.
Heat
If the air temperature is
cool, the air flows out
horizontally.
If the air is warm, the air
flows out in a downward
direction.
The left-hand and right-hand side flow directions can be adjusted manually.
Perform these adjustments before you start the device because once it has been started the slats vibrate and
there is a risk of your fingers getting caught.
Cool,
Dehumidify
Heat
Anleitung SKA 3500 C+H_GB 20.01.2006 9:14 Uhr Seite 14
15
Comfortable sleep mode function
Set this function if you desire a quiet room while sleeping.
Proceed as follows:
Press the key.
This function is for a quiet room while
sleeping.
Important:
Start this function just before you go to
sleep. If you start it during the day it is
possible that the ambient temperature will
become too hot, because the cooling
function is reduced.
To cancel this function: Press the key
again.
Anleitung SKA 3500 C+H_GB 20.01.2006 9:14 Uhr Seite 15
16
Full blast
If this function is started, every part of the room will be cooled.
Proceed as follows:
Press the key.
Press the key during full blast to stop
the operation. Once the full blast function
has been started the cool air will reach
every corner of the room.
The cancel:
Press the key again.
Anleitung SKA 3500 C+H_GB 20.01.2006 9:14 Uhr Seite 16
17
Timer mode (ON/OFF)
Set the TIMER mode before going to sleep, or for the normal time that you come home
or get up in the morning.
Timer On setting
1 Press the key during operation to set the
timer to “ON”. Each press of the key changes
the sequence Start time > Cancel.
2 Press the hours/minutes key to set
the current time.
Each press changes the time by 1 hour or 10
minutes. (AM=24.00-12.00; PM=12.00-
24.00)
To cancel
Press the key to cancel the timer setting.
Timer Off setting
1 Press the key during operation to set the
timer to OFF. Each press of the key changes
the sequence > Timer “OFF” switch off.
2 Press the hours and minutes key to
set the Timer OFF to the right time. Each
press changes the time by 1 hour or 10
minutes.
Switching off
Press the key to switch off the timer.
Important note:
- Timer ON and Timer OFF can be combined, with the setting time which is closest to the actual time having
priority. ( — — means Timer OFF, or Timer ON follows).
- If the clock setting on the remote control has not been correctly set, this will result in an incorrect setting on
the timer as well.
Anleitung SKA 3500 C+H_GB 20.01.2006 9:14 Uhr Seite 17
5. Tips on care
1. Clean the air filter and insert back in the original position.
2. Make sure that all inlets and outlets on the indoor and
outdoor device are kept clear and are not covered or
blocked.
Care precautions
Before cleaning:
Always pull out the power plug.
Care precautions
If the air conditioner is not going to be used for some period
of time:
1. Let the fans run for 3 - 4 hours to allow the device to
completely dry out. Set the highest possible temperature
level while the fans are running.
2. Switch off the device and pull the power plug.
Important:
Always pull out the power plug if the device is not going to be
used for some time. Collections of dust pose a fire hazard.
3. Take the batteries out of the remote control.
18
Important:
Always switch off the device and pull the power plug before cleaning. The high speed of the fans can cause
injury.
Clean the indoor device with a soft cloth only.
Never use petrol, thinners, scouring powder, cleaners, etc., as these may cause damage to the device.
Air filter
Anleitung SKA 3500 C+H_GB 20.01.2006 9:14 Uhr Seite 18
19
Device does not start. Check the following:
1. Is voltage present at the plug socket outlet?
2. Check the plug fuse!
3. Is the timer set?
The device does not provide satisfactory cooling!
Check the following:
1. Has an appropriate temperature been set?
2. Is the air filter soiled? Clean and fit back in place.
3. Are the inlets and outlets on the outdoor device blocked?
4. Has the sleep mode been set during the day?
5. Are the connections between the indoor and outdoor device adequately sealed? There may not be enough
coolant? If so, please contact your service company.
The remote control does not work!
(Important! It only works within a range of 6 m from the indoor device.)
1. Are the batteries still OK? Replace if necessary!
2. Have the batteries been inserted correctly? Check that the + and – terminals are correct!
In the event of a power failure, check the following:
Press the ON/OFF key after a power failure.
If the problems remain after checking through the above points, switch off the device and contact your service
company.
6. Troubleshooting
Before you ever contact customer services, check the following:
Anleitung SKA 3500 C+H_GB 20.01.2006 9:14 Uhr Seite 19
20
Troubleshooting
Problem
After pressing the start key the device is not started
by the microprocessor for 3 minutes.
Crackling noises can be heard.
There is an odd smell in the room.
The fan stops during dehumidifying.
You can hear moving water.
The air flow changes automatically during operation.
There is a clicking noise inside the indoor device.
There is a muffled noise coming from the indoor
device.
Water drops from the outdoor device.
Air is not blown out immediately in heat mode.
The air conditioner switches off during heat mode.
Cause
This is not a fault, it is for the protection of the
compressor. Please have a little patience.
This is not a fault.
These tension noises are caused by the contraction
and expansion of the front panel in response to
temperature differences.
This is not a fault.
The air conditioner also circulates the transpiration
from the walls, carpets, smoke, furniture and clothing
in the air.
This is not a fault.
The temperature increases when water evaporates
on the heat exchanger in the indoor device.
This is not a fault.
The coolant in the air conditioner may have
expanded.
This is not a fault.
The ventilation slats turn to a horizontal position to
prevent dripping if the air has been blown downwards
for approx. 1 hour in the cool or dehumidifying
function. If the blast air is too cool, it will also be
blown out horizontally.
This is not a fault.
This will normally be the noise of the fan or the
compressor when switching on or off.
This is not a fault.
This noise comes from the coolant in the air
conditioner.
This is not a fault.
During the cooling process the tube or the connection
pieces cool down in order to form the condensate.
During defrosting or heating the evaporation
condensate may drip. During heating, water may drip
from the heat exchanger.
This is not a fault.
Air only starts to be blown out once it has been
heated up.
The outdoor device freezes if the outdoor
temperature is low (below approx. +7°C). Heat mode
is not possible if the outdoor temperature is below
approx. +7°C.
Anleitung SKA 3500 C+H_GB 20.01.2006 9:14 Uhr Seite 20
21
Over 15 cm, if the tube connection
is from the left or the back.
o
v
e
r
2
0
c
m
o
v
e
r
2
0
c
m
over 300 cm
over 2,3 m
over50 cm
o
v
e
r
3
0
c
m
o
v
e
r
3
0
c
m
o
ve
r 5
0
cm
over 200 cm
Selecting the place to install the indoor device
The air flow must never be blocked.
The cooled air should be capable of being
distributed to all parts of the room.
The maximum distance between the indoor and
outdoor device is 15m and their maximum
difference in height 5m.
Mount on a solid wall to prevent vibrations.
Avoid direct sunlight.
Take into account a slight condensate run-off.
Selecting the place to install the outdoor device
The device must not be exposed to strong gusts of
wind.
Make sure that the device is well ventilated and
kept free of dust. Avoid direct exposure to rain and
sunlight.
Make sure that the operational noises and air
emissions do not cause a nuisance for neighbours.
Install on a firm base, avoiding excessive noise or
vibrations.
Avoid locations where combustible gas or leakage
can be emitted.
Fix the device’s installation feet with care if the
device is to be installed well above them.
Important
Do not hesitate to contact our service partners.
They will be able to give you a speedy response to
all your questions so that your system can be
installed correctly. We shall accept no liability for
services if the air conditioner is not installed, vented
and put into operation for the first time by an air
conditioning specialist.
Mounting accessories
Mounting plate
Screws 4x25 mm
Batteries 2 x MICRO LR03 1.5V
Remote control
Tubing accessories
Tube connector
Composite wrap-around tape
Klamb
Drainage hose
Connection cable
The following pages are intended for professional installers.
7. Important installation instructions
Anleitung SKA 3500 C+H_GB 20.01.2006 9:14 Uhr Seite 21
22
8. Installation instructions:
Check that the actual mains voltage is the same
as the mains voltage specified on the rating
plate.
The device must have separate protection
against short-circuits.
Have all work of electrical installation performed
by an electrician.
Ask a service partner or specialist cooling
system firm to undertake all work of installing the
cooling system.
Incorrect installation can lead to injury or damage
to property.
Always wear ear muffs, goggles and work gloves
when performing work of installation.
Notes on electrical connection!
All electrical connection work must be performed by
a qualified electrician authorized to do so such work
by the applicable electricity supply company. The
system must have separate protection against short-
circuits. Select a suitably large cable cross-section.
The yellow/green wire is to be used as a protective
conductor only and under no circumstances as a
voltage carrying conductor. The fixed electrical
connection of the device must be capable of being
isolated from the mains power supply by a device
with an isolating distance of at least 3mm (e.g.
circuit-breaker). Connect the electrical connections of
the indoor and outdoor devices together first and
then connect to the mains power supply. Check first
that the entire system is voltage-free. Secure the
system from being switched on again.
1. Selecting the place of installation
Indoor device
1. The openings for the inlet and outlet air must
never be covered, otherwise the air will not be
distributed throughout the entire room.
2. Install the indoor device in a location which
ensures that the distance through the wall to the
outdoor device is as short as possible.
3. Make sure that the drainage hose does not have
any kinks or upward inclines when you connect it
with the outside.
4. Do not select a location adjacent to a source of
heat, high humidity or inflammable gas.
5. Select a location which is firm enough for
installation so that the device is not subjected to
vibrations.
6. Check that the device has been installed
correctly and exactly.
7. Make sure that there is sufficient space available
for later repair and service work.
8. The device should be installed at a distance of at
least 1 m from all other electrical devices and
installations, e.g. TV, radio, computer, etc.
9. Select a location for the device which is easily
accessible so that the filter can be cleaned or
replaced without difficulty.
Outdoor device
1. Select a location which avoids causing a
nuisance to neighbours from noise and air
emissions from device.
2. Select a location which is sufficiently well
ventilated.
3. Never cover the air inlets and outlets.
4. The location must be sufficiently firm for
installation and the prevention of vibrations.
5. There must be no risk presented by combustible
gas or gas escaping as a result of corrosion.
6. Check that the device is installed in accordance
with regulations.
Important:
The following could cause malfunctions.
Check with your service company in order to
prevent possible malfunctions at a later date.
The following locations should be avoided for
installation:
A location where oil (machine oil) is stored.
A location where there is a high salt content.
A location with numerous sulphurous sources,
e.g. spa zones.
A location where radio transmitters or amplifier
aerials, welding equipment or medical equipment
are in use.
A location where the outdoor device is exposed
to direct sunlight. If necessary the device must
be protected with a sun-shade. Such a sun-
shade must not interfere with the air flow,
however.
A location in the vicinity of heat or steam
generators.
A location which is heavily exposed to dust.
A location to which the general public have
access.
A location with any other unusual characteristics.
Important!
The direction in which the air is blown should
correspond with the prevailing direction of the
wind.
Never install in locations exposed to aggressive
Anleitung SKA 3500 C+H_GB 20.01.2006 9:14 Uhr Seite 22
23
air.
Comply with all specified minimum distances
(see Important notes on installation).
The indoor and outdoor devices must only ever
be installed in a vertical position.
2. Installing the indoor device
It is imperative that you comply with the installation
instructions.
2.1 Before you start installation
Select the location for the indoor device (follow
the previous notes on selecting the location for
installation).
Check that the available mains voltage is the
same as the voltage specified on the rating plate.
Fit appropriate insulation, supplied by the
customer, to the coolant tubes.
2.2 Fitting the mounting plate
The mounting plate for the indoor device must be
fitted horizontally to the wall. In doing so, it is
imperative that you comply with all specified
distances. Mark and drill the holes for fastening
the mounting plate, and then firmly fasten with
dowels and screws. In order to prevent vibrations
on the indoor device, make sure that there are
no gaps between the wall and the mounting
plate.
2.3 Drilling the hole through the wall
Drill the hole through the wall for the lines/hoses
using a 65mm drill bit, drilling from the inside to
the outside at an angle downwards of approx. 5°.
Then insert the wall hole tube in the hole in the
wall.
2.4 Fitting the condensation water drainage hose
The drainage water hose must be run to the
outside with a drop. It is imperative that there are
no bends or kinks. The end of the drainage hose
must not be situated in a container of any kind in
which water can collect. Any water held back in
the drainage water hose could lead to water
damage.
Slide the additional drainage hose onto the
mounts on the drainage hose already fixed to the
indoor device. Fasten this connection point with
adhesive tape, checking that it is fully sealed as
you do so. Wrap the section of the drainage hose
in the hole in the wall, plus approx. 10 cm in front
of the wall on both the inside and outside, in
insulation material.
2.5 Wrapping the lines/hoses in protective tape
Please note that the power cable is not to be fed
through to the outside. All tubes, electric cables
and the drainage water hose have to be wrapped
with the supplied protective tape. Depending on
whether the lines are right-hand or left-hand
versions, the corresponding bushing
preparations must be removed from the indoor
device.
2.6 Final installation of the indoor device
Feed the package of lines/hoses through the
hole in the wall.
Fit the indoor device to the hook at the top of the
mounting plate and let it lock into place at the
bottom.
The package of lines/hoses is to be laid between
the housing of the indoor device and the wall. In
order to prevent condensation water, insulate the
package of lines/hoses with heat insulation
material.
3. Assembly of the outdoor device
Have the connection cable for the outdoor device
connected only by a qualified electrician
inside Outside
Inside
Insert the wall
hole tube
Outside
Inside
Insulation
Drainage hose
electric
cable
Drainage hose
Protective tape
Coolant
hose
additional drainage
hose
Wall
Anleitung SKA 3500 C+H_GB 20.01.2006 9:14 Uhr Seite 23
24
4. Connecting the coolant tubes
4.1 Important notes
Please make sure that coolant is never allowed
to enter the environment.
Improper handling of coolant may be harmful to
health. Always wear work gloves and goggles
when handling coolant.
Make sure that the work place is well ventilated
at all times. Smoking is prohibited.
The device must never be operated without the
coolant tubes connected, otherwise the device
will be damaged immediately.
Ask one of our service partners or a specialist
cooling system firm to connect the coolant lines
and put the system into operation for the first
time.
5. Remote control holder
Before you mount the holder, check that the remote
control can be received by the indoor device from the
planned location for the holder. Do not select a
position in direct sunlight or in the vicinity of any
sources of heat.
Check that the + and – terminals on the batteries
are positioned correctly in the remote control.
Fasten the remote control holder to the wall with
dowels and screws.
6. Electrical connections
1. Remove the fresh air connection part.
2. Remove the connection terminal and connect the
mains cable to the connection element with the
screws. Make sure that the wiring conforms with
the indoor device.
3. Fix the wires in position with the terminal and
make the necessary connections.
4. Check once again that connections are really
secure.
5. Re-fasten the fresh air part.
Note:
A wrong electrical connection can cause
faults in the electrical system. Do not pull
on the cable when you connect it to the
terminal.
Important
1. Have all service work performed by a specialist
firm only. Request a copy of our list of service
partners for any such work.
2. If ever the voltage carrying cable between the
indoor device and the outdoor device should be
damaged, contact a specialist firm.
3. If the power cable should ever be damaged,
have it replaced by an electrician.
4. Important note:
a) The maximum length of the coolant line in the
basic version is 4 meters.
b) If the outdoor device is higher than the indoor
device, a curve will be required in the coolant
tube which is positioned below the height of the
indoor device.
Anleitung SKA 3500 C+H_GB 20.01.2006 9:14 Uhr Seite 24
25
indoor device
ET-Nr. 23.709.21.00
Connection cable
outdoor device
ET-Nr. 23.709.25.00
grey
blue
yellow/green
black
brown
1234
1234
cable
Stress-relief
clip
Anleitung SKA 3500 C+H_GB 20.01.2006 9:14 Uhr Seite 25
25


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Einhell SKA 3500 C-H at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Einhell SKA 3500 C-H in the language / languages: English as an attachment in your email.

The manual is 0,87 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Einhell SKA 3500 C-H

Einhell SKA 3500 C-H User Manual - German - 40 pages

Einhell SKA 3500 C-H User Manual - Dutch - 32 pages

Einhell SKA 3500 C-H User Manual - French - 32 pages

Einhell SKA 3500 C-H User Manual - Italian - 32 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info