724163
18
Zoom out
Zoom in
Previous page
1/24
Next page
18
Never install in locations exposed to aggressive
air.
Comply with all specified minimum distances
(see Important notes on installation).
The indoor and outdoor devices must only ever
be installed in a vertical position.
2. Installation accessories
Before any work on installing the system is started,
please check that all installation accessories have
been included.
Item Description Number of items
1 Mounting plate 1
2 Wall hole cap 2
3 Remote control with holder 1
4 Micro LR03 1.5V battery 2
5 Plastic wrap-around tape 1
6 Insulation tape 1
7 Sealing compound 1
3. Installing the indoor device
It is imperative that you comply with the installation
instructions.
3.1 Before you start installation
Select the location for the indoor device (follow
the previous notes on selecting the location for
installation).
Check that the available mains voltage is the
same as the voltage specified on the rating plate.
Fit appropriate insulation, supplied by the
customer, to the coolant tubes.
3.2 Fitting the mounting plate
The mounting plate for the indoor device must be
fitted horizontally to the wall. In doing so, it is
imperative that you comply with all specified
distances. Mark and drill the holes for fastening
the mounting plate, and then firmly fasten with
dowels and screws. In order to prevent vibrations
on the indoor device, make sure that there are
no gaps between the wall and the mounting
plate.
3.3 Drilling the hole through the wall
Drill the hole through the wall for the lines/hoses
using a 65mm drill bit, drilling from the inside to
the outside at an angle downwards of approx. 5°.
Then insert the wall hole tube in the hole in the
wall.
3.4 Fitting the condensation water drainage hose
The drainage water hose must be run to the
outside with a drop. It is imperative that there are
no bends or kinks. The end of the drainage hose
must not be situated in a container of any kind in
which water can collect. Any water held back in
the drainage water hose could lead to water
damage.
Slide the additional drainage hose onto the
mounts on the drainage hose already fixed to the
indoor device. Fasten this connection point with
adhesive tape, checking that it is fully sealed as
you do so. Wrap the section of the drainage hose
in the hole in the wall, plus approx. 10 cm in front
of the wall on both the inside and outside, in
insulation material.
3.5 Wrapping the lines/hoses in protective tape
Please note that the power cable is not to be fed
through to the outside. All tubes, electric cables
and the drainage water hose have to be wrapped
with the supplied protective tape. Depending on
whether the lines are right-hand or left-hand
versions, the corresponding bushing
preparations must be removed from the indoor
device.
3.6 Final installation of the indoor device
Feed the package of lines/hoses through the
hole in the wall.
inside Outside
Inside
Insert the wall
hole tube
Outside
Inside
Insulation
Drainage hose
electric
cable
Drainage hose
Protective tape
Coolant
hose
additional drainage
hose
Wall
Anleitung SKA 2501 C GB 22.12.2004 17:23 Uhr Seite 18
18


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Einhell SKA 2501C at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Einhell SKA 2501C in the language / languages: English as an attachment in your email.

The manual is 1,37 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Einhell SKA 2501C

Einhell SKA 2501C User Manual - German - 24 pages

Einhell SKA 2501C User Manual - Dutch - 24 pages

Einhell SKA 2501C User Manual - French - 24 pages

Einhell SKA 2501C User Manual - Italian - 24 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info