28
outdoor device to the plug-coupling system on
the outdoor device.
Fasten the connector cable to the outdoor device
using the cable clamps.
Screw the connection guard back on the outdoor
device.
Fasten the complete package of lines, with the
protective tape wrapped around them, to the outside
wall using the supplied plastic clamps.
7. Remote control holder
Before you mount the holder, check that the remote
control can be received by the indoor device from the
planned location for the holder. Do not select a
position in direct sunlight or in the vicinity of any
sources of heat.
Check that the + and – terminals on the batteries
are positioned correctly in the remote control.
Fasten the remote control holder to the wall with
dowels and screws.
Important
1. Have all service work performed by a specialist
firm only. Request a copy of our list of service
partners for any such work.
2. If ever the voltage carrying cable between the
indoor device and the outdoor device should be 1.
damaged, contact a specialist firm.
3. If the power cable should ever be damaged,
have it replaced by an electrician.
4. Important note:
a) The maximum length of the coolant tube is 4
meters.
b) If the outdoor device is higher than the indoor
device, a curve will be required in the coolant
tube which is positioned below the height of the
indoor device.
Connector cable
outdoor device
connector cable
indoor device
Cable clamp
Cable clamp
Cable clamp
Plug-coupling
system