25
previous notes on selecting the location).
Check that the available mains voltage is the
same as the voltage specified on the rating plate.
The maximum possible distance between the
indoor and the outdoor device using the supplied
accessories is 4 m.
If the outdoor device is higher than the indoor
device, make sure that a curve is made in the
coolant tube which is lower than the bottom edge
of the indoor device.
Fasten the condensation water drain to the base
of the outdoor device.
3.2 Mounting the outdoor device
The outdoor device can be fastened to the
ground or to a wall bracket (e.g. special
accessory Art. No. 23.651.55) with dowels and
screws. To do so, use the holes on the device.
4. Connecting the coolant tubes
4.1 Important notes
Please make sure that coolant is never allowed
to enter the environment.
Improper handling of coolant may be harmful to
health. Always wear work gloves and goggles
when handling coolant.
Make sure that the work place is well ventilated
at all times. Smoking is prohibited.
The device must never be operated without the
coolant tubes connected, otherwise the device
will be damaged immediately.
Ask one of our service partners or a specialist
cooling system firm to connect the coolant lines
and put the system into operation for the first
time.
5. Remote control holder
Before you mount the holder, check that the remote
control can be received by the indoor device from the
planned location for the holder. Do not select a
position in direct sunlight or in the vicinity of any
sources of heat.
Check that the + and – terminals on the batteries
are positioned correctly in the remote control.
Fasten the remote control holder to the wall with
dowels and screws.
6. Electrical connection
Important note: All work of making the electrical
connection of the system must be undertaken by an
electrician.
Remove the connection cover on the outdoor
device.
Connect the electric cable as shown in the
illustration; take account of the ground terminal
as you do so.
Secure the electric cable on the outdoor device
with a cable grip.
Fit the connection cover back on the outdoor
device.
Inddor device
Outddor device
Curve
Coolant tube