3. Scope of use
The compressor is designed for generating
compressed air for tools operated by compressed
air.
Please note that our equipment has not been
designed for use in commercial, trade or industrial
applications. Our warranty will be voided if the
machine is used in commercial, trade or industrial
businesses or for equivalent purposes.
The machine is to be used only for its prescribed
purpose. Any other use is deemed to be a case of
misuse. The user / operator and not the
manufacturer will be liable for any damage or injuries
of any kind caused as a result of this.
4. Technical data
Power supply: 400 V 3~ 50 Hz
Motor rating in kW/HP: 2.2/3.0
Compressor speed in rpm: 2850
Operating pressure in bar: max. 10
Pressure vessel volume in litre: 100
Theoretical intake rate in l/min.: 400
Sound power level L
WA
in dB: 91.8
Sound pressure level L
pA
in dB: 71.8
Protection type: IP44
Machine weight in kg: 70
5. Points to note when setting up the
compressor
Examine the machine for signs of transit
damage. Report any damage immediately to the
company which delivered the compressor.
The compressor should be set up near the
working consumer.
Avoid long air lines and long supply lines
(extensions).
Make sure the intake air is dry and dust-free.
Do not set up the compressor in damp or wet
rooms.
The compressor may only be used in suitable
rooms (with good ventilation and an ambient
temperature from +5°C to +40°C). There must be
no dust, acids, vapors, explosive gases or
inflammable gases in the room.
The compressor is designed to be used in dry
rooms. It is prohibited to use the compressor in
areas where work is conducted with sprayed
water.
The oil level in the compressor pump has to be
checked before putting the equipment into
operation.
6. Assembly and starting
Important!
You must fully assemble the appliance before
using it for the first time.
6.1 Fitting the wheels (3/4)
Fit the supplied wheels as shown in Fig. 6-7.
6.2 Fitting the quick-lock coupling for tank
pressure (13)
Screw the quick-lock coupling for unregulated tank
pressure (13) to the pressure vessel (2) as shown in
Figures 8 to 9.
6.3 Fitting the transport handle (9)
Screw the transport handle (9) to the compressor as
shown in Figures 10 to 12.
6.4. Replacing the oil sealing plug (14)
Remove the transportation cover from the oil filler
opening with a screwdriver and insert the supplied oil
sealing plug (14) into the oil filler opening (Fig. 13).
6.5. Power supply
The compressor is equipped with a mains cable
with a 16A CEE plug. This plug has a phase
converter . Before you put the equipment into
operation, check whether the motor rotates in the
correct direction (see the direction arrow on the
V-belt cover) by switching on the compressor
briefly. If the compressor motor rotates in the
wrong direction, you must correct the rotating
field by reversing the phase converter in the plug
(use a screwdriver to depress the phase
converter slightly and turn it through 180°).
The motor is equipped with an overload switch. If
the compressor overloads, the overload switch
will switch off the equipment automatically to
protect the compressor from overheating. If the
overload switch triggers, wait for the compressor
to cool down.
Long supply cables, extensions, cable reels etc.
cause a drop in voltage and can impede motor
start-up.
In the case of low temperatures below +5°C,
GB
15
Anleitung_RT_AC_400_100_10_D_SPK1:_ 17.06.2008 16:26 Uhr Seite 15
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Einhell RT-AC 400-100-10 D at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Einhell RT-AC 400-100-10 D in the language / languages: English, Danish, Norwegian as an attachment in your email.

The manual is 3,59 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Einhell RT-AC 400-100-10 D

Einhell RT-AC 400-100-10 D User Manual - German, Dutch, French, Italian, Portuguese, Spanish - 56 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info