MR 920/2
Rated voltage: 220-240 V ~ 50 Hz
Output: 2000 W (800 W / 1200 W)
Thermostat control: Infinitely adjustable
Heating ribs: 9
Protection class: I
MR 1125/2
Rated voltage: 220-240 V ~ 50 Hz
Output: 2500 W (1000 W / 1500 W)
Thermostat control: Infinitely adjustable
Heating ribs: 11
Protection class: I
6. Before starting the equipment
Important! Before using the appliance for the first
time, check that the voltage supply is the same as
the voltage details set out on the data plate.
Read safety instructions listed under section 1.
6.1 Fitting the castors (Fig. 2 – 4)
Important! To prevent damage, place the radiator
upside down on a soft surface (for example a
carpet).
n Place 2 castors (6) on each castor carrier (A) and
secure them with the cap nut (B).
n Slide the fastening bar (C) under the radiator
element (A) and secure the castors carrier with the
wing nuts (D). Repeat the above on the last space
between the ribs.
7. Operation
If the equipment should topple or fall over, the power
supply will be cut off by a safety switch integrated in
the equipment. The power supply resumes as soon
as the equipment is stood upright again.
When the equipment is used for the first time or after
a long period of rest it may emit an odor for a short
time. This is not a fault.
7.1 Function switch (Fig. 5 / Item 3):
n Low heat output – Switch in position "I"
n Medium heat output – Switch in position "II"
n High heat output – Switch in position "I+II"
The possible output levels are listed in the technical
data in point 5.
Note:
For safety reasons, the heater will switch off at a
certain heating rib temperature in order to prevent
overheating of the heating ribs at maximum heat
output. The heater will switch on again and the
heating cycle will restart as soon as the heating ribs
have cooled down to a certain temperature. This is
not an equipment defect.
7.2 Thermostat control/Room thermostat
(Fig. 5 / Item 4):
Note: When the equipment is moved to a new
location, the thermostat will not work properly until
the equipment has adopted the ambient temperature.
Switch on the required output using the two function
switches. Turn the control to “MAX” until the required
room temperature has been reached. Then turn
down the control until you hear a clear click. The
thermostat control will switch the radiator on and off
automatically to maintain the room temperature at an
almost constant level. However, this presupposes
that the radiator has a sufficient output to cover the
heating requirements for the room.
8. Cleaning, maintenance and ordering
of spare parts
8.1 Cleaning
Danger!
n Before carrying out any cleaning and
maintenance work the equipment must be turned
off, disconnected from the power supply and
cooled down.
n Use a damp cloth to clean the casing.
n Remove dust pollution with a vacuum cleaner.
8.2 Servicing
n Maintenance and repair work may only be carried
out by an electrical servicing contractor or ISC
GmbH.
n Check the mains lead at regular intervals for signs
of defects or damage. A damaged mains lead
may only be replaced by an electrician or ISC
GmbH in compliance with the relevant
regulations.
n There are no parts inside the equipment which
require additional maintenance.
10
GB
Anleitung_MR_920_2_SPK7__ 09.03.15 15:32 Seite 10
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Einhell MR 715-2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Einhell MR 715-2 in the language / languages: English, German, Dutch, French, Italian, Polish, Swedish, Turkish, Finnish as an attachment in your email.

The manual is 1,16 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info