735389
7
Zoom out
Zoom in
Previous page
1/44
Next page
GB
7
it with the wing nut (3). Repeat the above on the
last space between the ribs.
4. Technical data:
MR 510
Rated voltage: 230 V ~ 50 Hz
Output: 1000 W (500 W/1000 W)
Thermostat control: Infinitely adjustable
Heating ribs: 5
Protection class: I
Mains lead: 3 x 1 mm
2
x 1,25 m
MR 715
Rated voltage: 230 V ~ 50 Hz
Output: 1500 W (600 W/900 W/1500 W)
Thermostat control: Infinitely adjustable
Heating ribs: 7
Protection class: I
Mains lead: 3 x 1 mm
2
x 1,25 m
MR 920
Rated voltage: 230 V ~ 50 Hz
Output: 2000 W (800 W/1200 W/2000 W)
Thermostat control: Infinitely adjustable
Heating ribs: 9
Protection class: I
Mains lead: 3 x 1 mm
2
x 1,25 m
5. Proper use
The appliance is designed only for private use, not
for commercial heating purposes.
6. Starting up
Important! Before using the appliance for the first
time, check that the voltage supply is the same as
the voltage details set out on the data plate.
Read safety instructions listed under section 1.
6.1 Function switch (Fig. 4):
MR 510:
Low output – activate switch (1) or switch (2)
Maximum output – activate switches (1+2)
MR 715/MR 920:
Low output – activate switch (1)
Medium output – activate switch (2)
Maximum output – activate switches (1+2)
The possible output levels are listed in the technical
data in point 4.
6.2 Thermostat control/Room thermostat
(Fig. 4 / Item 3):
Switch on the required output using the two function
switches. Turn the control to “MAX” until the required
room temperature has been reached. Then turn
down the control until you hear a clear click. The
thermostat control will switch the radiator on and off
automatically to maintain the room temperature at an
almost constant level. However, this presupposes
that the radiator has a sufficient output to cover the
heating requirements for the room.
7. Storage
If the radiator is not used for a lengthy period of time,
the mains lead must be stored in full in the
compartment provided for it. The radiator has to be
stored in a dry place, covered if possible.
8. Maintenance and cleaning
Maintenance and repair work may only be carried
out by an authorized electrical servicing contractor
or the customer service responsible for your
country.
Check the mains lead at regular intervals for signs
of defects or damage. A damaged mains lead may
only be replaced by an electrician or the customer
service responsible for your country in compliance
with the relevant regulations.
Important: Disconnect the mains lead before
cleaning – danger of electric shock.
Use a damp cloth to clean the casing.
The ribs are filled with a special oil. Repairs that
necessitate the oil seal to be opened may only be
carried out by the customer service responsible for
your country. If oil leaks from the appliance, return
it to the customer service responsible for your
country for examination.
Anleitung Ölradiator SPK7 04.04.2006 14:42 Uhr Seite 7
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Einhell MR 510 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Einhell MR 510 in the language / languages: English, German, Dutch, French, Italian, Polish, Swedish, Spanish, Finnish as an attachment in your email.

The manual is 0,38 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info