Accessories
11 Exhaust air connection fittings
12 Bushing ring
13 Exhaust air hose
14 Foam material (Used for exhaust air outlet
through the window.)
15 Foam material (Used for exhaust air outlet
through the open window and placed in the open
section of the window. As far as possible, no
additional warm air should come into the room
from outside.)
16 Cap for the hole in the window/wall
17 Collection tank for the condensation water
18 Drainage water hose
19 Remote control (MKA 3501 E)
20 Activated carbon filter
Description of the control elements
MKA 2000 M / MKA 3000 M
1. Voltage display
2. Fan status indicator
3. Cooling status indicator
4. Condensation water tank “Full” indicator
5. Thermostat (+18°C to +32°C)
6. Cooling and fan switch
Low Fan; High Fan; Low Cool; High Cool and Off
function
7. Timer controller
1 - 8 hours can be set. The timer controller can be
used to switch the system on/off.
Off = System switched off
Low Fan = Fan runs at slow speed
High Fan = Fan runs at high speed
Low Cool = Low cooling
High Cool = High cooling
Using the device for the first time
MAINS PLUG Plug the mains plug into the mains
socket outlet.
START Set the timer controller to ON. The
device starts up automatically.
Whenever the temperature
exceeds 23°C the cooling function
starts automatically. Whenever
the temperature is below 23°C,
only the fan will run. The device
keeps running until it is switched
off.
SWITCHING OFF Turn the timer controller to “OFF”
and the device switches off
immediately.
Setting the temperature
Set the thermostat according to your requirements.
Turning in a clockwise direction reduces the set-point
temperature.
Setting the timer
Set the timer according to your requirements (1 – 8
hours). The device switches off automatically once
the set time has elapsed.
12
GB