Inserting battery (Figure 8):
1. Open the battery compartment cover.
2. Slide the battery into the battery compartment
from the right to left. Make sure that the right,
bottom battery contact is in connection with the
negative pole and the left, top battery contact
with the positive pole of the battery.
3. Close the battery compartment cover.
6.10 Setting the direction of the air (Fig. 1/Item 2)
The horizontal direction of the air flow is determined
by the horizontal ventilation grille. It has to be
adjusted by hand.
6.11 Draining the condensate in the condensate
tray (Fig. 9)
For the cooling mode the device is fitted with a
condensate return unit. When the system is in
operation the condensate is collected in a trough
(approx. contents 1.2 liters) integrated in the device.
From there it is evaporated by the condenser and
transferred outside by the exhaust air hose.
Note:
If the humidity in the room exceeds 85% (RH), a
condensate drainage hose (see section “6.10”) is
absolutely essential.
ALL OF THE CONDENSATE MUST BE DRAINED
OFF BEFORE YOU EVER RELOCATE OR STOP
USING THE DEVICE.
Note:
When the condensate tray is full the compressor and
the fan motor shut down. The “W.F.” LED flashes
and a signal sounds. The signal can be disabled by
pressing any button. The unit will then be shut down
completely.
When this happens, empty the tray as described
below:
1. Switch off the unit, pull the plug and do not move
the unit.
2. Push a container under the drain screw (1).
3. Unscrew the drain screw (1).
4. Remove the rubber bung (2) from the drain
opening (3).
5. The condensate runs into the container. If the
container is smaller than the condensate tray,
seal the drain opening (3) with the rubber bung
(2) and empty the container. Then repeat the
process from point 4.
6. Once the condensate tray has been completely
emptied, fit the bung (2) and the drainage screw
(1) again.
7. Start the unit again. The “W.F.” LED will no
longer flash.
6.12 Draining the condensate with a hose
(Fig. 9-10)
ALL THE CONDENSATE MUST HAVE BEEN
DRAINED BEFORE YOU START THE
FOLLOWING PROCESS.
1. Switch off the unit and pull the power plug.
2. Unscrew the drain screw (1).
3. Remove the rubber bung (2) from the drain
opening (3).
4. Connect the condensate drainage hose (4) and
secure it with a clip
5. The drainage hose can be extended with a hose
(5) with a diameter of 18mm. If you do so, make
sure you use a suitable connector.
Note:
The drainage hose must run to the outside with a
slight fall. The “Condensate tray full” indicator is not
operational.
7. Cleaning, maintance and
ordering of spare parts
To avoid an electric shock or risk of fire,
always pull out the mains plug first before
starting any cleaning work .
7.1 Cleaning the air filter
The air conditioner is fitted with 2 filters.
1. Dust filter (close-meshed filter net)
2. Activated carbon filter (binds particles in the air
and prevents the development of bacteria)
Important: Never use the device without air filters.
1) Dust filter
Use a vacuum cleaner or tap the dust filter gently to
remove the dust. If the filter is very dirty, wash it
carefully with warm water. Then allow to dry
thoroughly.
2) Activated carbon filter
The activated carbon filter is located behind the top
dust filter and cannot be washed. Its service life is
dependent on the operating conditions. The filter
should be inspected and replaced if necessary. The
filter cover then has to be fitted back on the device
with the activated charcoal filter.
7.2 Cleaning the housing
Use only gentle cleaner and a soft cloth to clean
the housing. Never use aggressive media, petrol,
alcohol or thinner. Only fit the filter back in place
when thoroughly dry.
GB
18
Anleitung_MKA_3000_E_SPK7:_ 08.11.2010 9:41 Uhr Seite 18
18


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Einhell MKA 3000E at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Einhell MKA 3000E in the language / languages: English, German, French, Italian, Swedish, Turkish, Spanish as an attachment in your email.

The manual is 1,7 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info