686718
15
Zoom out
Zoom in
Previous page
1/92
Next page
GB
- 15 -
8. Using an external condensate
drain (Fig. 4-5)
Note:
Important: To prevent water damage, make
sure that the condensate is drained away pro-
perly at all times.
Important: If the weather is very cold you will
have to take appropriate measures to prevent
the water from freezing in the drainage hose.
It is best to direct the condensate into a lower
lying drain. If you use an external collecting
container (e.g. a trough), the equipment must
be positioned accordingly higher.
The drainage hose must be installed with a
downward gradient. It must not be kinked or
become clogged.
If the drainage hose becomes clogged, the
condensate must run into the condensate
collector from the overflow.
1. Remove the condensate collector (7).
2. Remove the rubber plug and keep it in a safe
place (it must be reinserted in the connection
socket when the external condensate drain is
no longer used).
3. Connect the suction port with a matching wa-
ter hose (C) with a 10 mm inside diameter.
4. Place the condensate collector (7) back in the
equipment and pass the water hose (C) to the
outside.
De-icing function
To prevent the cooling elements becoming iced
up at operating temperatures below 21°C, the
equipment has a de-icing function. In this case
the compressor is switched o but the fan motor
continues to run.
During this phase the dehumidifying function is
interrupted for a few minutes.
Please observe the equipment’s operating range
(see Technical Data).
The equipment has a compressor protector which
automatically shuts down the equipment when
the temperature rises above 35°C or falls below
5°C, or when the power consumption rises too
high.
9. Cleaning, maintenance and
ordering of spare parts
Be sure to pull out the power plug before
doing any maintenance and cleaning work!
Use only a soft cloth to clean the casing.
Do not use any aggressive chemicals, deter-
gents, chemically treated cleaning cloths or
solvents. They could damage the casing.
Cleaning the air lter (every 2 weeks)
Remove the air filter cover (Fig. 6 / Item 5).
Use a vacuum cleaner.
If the filter is very dirty, wash it with warm wa-
ter (max. 40°C). Then allow it to dry thorough-
ly. Never expose the filter to the sun or other
sources of heat. Never reinsert the filter while
it is still damp.
Maintenance
There are no other parts inside the equipment
which require maintenance.
Storage
If you are not going to use the dehumidi er for
some time, proceed as follows:
Switch off the equipment, pull out the power
plug and roll up the power cable.
Empty the water collector and dry it thorough-
ly.
Clean the ventilation grille and the dust filter
cover the equipment and store it in a dry and
dust-free place.
Ordering replacement parts:
Please quote the following data when ordering
replacement parts:
Type of machine
Article number of the machine
Identification number of the machine
Replacement part number of the part required
For our latest prices and information please go to
www.isc-gmbh.info
10. Storage
Store the equipment and accessories in a dark
and dry place at above freezing temperature. The
ideal storage temperature is between 5 and 30
°C. Store the electric tool in its original packaging.
Anl_LE_10_SPK7.indb 15Anl_LE_10_SPK7.indb 15 03.03.16 08:1403.03.16 08:14
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Einhell LE 10 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Einhell LE 10 in the language / languages: English, German, Dutch, French, Italian, Portuguese, Spanish as an attachment in your email.

The manual is 1,73 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info