16
Re-tighten the locking nut (13) and make the cut
as described in Section 7.2.
7.6 Precision adjustment of the stop for 45° mitre
cuts (Fig. 2/4/8)
Lower the machine head (4) and fix with the lock
pin (16).
Fix the rotary table (8) in 0° position.
Undo the locking nut (13) and, holding the handle
(2), tilt the machine head (4) to the left by 45°
Place the 45° stop angle (b) between the saw
blade (5) and the rotary table (8).
Slacken the counter nut and adjust the setting
screw (22) until the angle between the saw (5)
and the rotary table (8) equals exactly 45°.
Re-tighten the locking nut (13) and make the cut
as described in Section 7.2.
7.7 Mitre cuts 0°-45° and rotary table 0°-45°
(Fig. 4/9)
The KGSZ4300 can be used to make mitre cuts on
the left at an angle of 0°-45° relative to the work top
and 0°-45° relative to the stop rail.
Lift the machine head (4) to its top position.
Release the turntable (8) by loosening the locking
grip (10).
Adjust the rotary table (8) by its handle (2) to the
required angle (see also Section 7.4).
Re-tighten the locking handle (10) to fix the rotary
table in position.
Undo the clamping nut (13) and, holding the
handle (2), tilt the machine head (4) to the left to
the required angle dimension
(see also Section 7.5).
Re-tighten the locking nut (13) and make the cut
as described in Section 7.2.
7.8 Chip extraction (Fig. 1)
The saw is equipped with a chip collection bag (24).
The chip bag (24) can be emptied by opening the zip
fastener at the bottom.
7.9 Replacing the saw blade (Fig. 11)
Pull out the power plug.
Swing up the machine head (4).
Press the lever and swing up the saw blade
guard to the point where the recess in the saw
blade guard is above the flange bolt.
Press the saw shaft lock (17) with one hand while
holding the wrench (31) on the flange bolt with
the other.
Firmly press on the saw shaft lock (17) and
slowly rotate the flange bolt in clockwise
direction. The saw shaft lock engages after no
more than one rotation.
Now, using a little more force, slacken the flange
bolt in clockwise direction.
Turn the flange bolt until it is completely
removed.
Take the blade (5) off the inner flange and pull
out downwards.
Mount the new saw blade in reverse order and
fasten.
Important! The cutting bevel of the teeth, i.e. the
direction of rotation of the saw blade, has to
conform with the direction of the arrow marked on
the housing.
Clean the saw blade flanges thoroughly before
mounting the saw blade.
Reattach the movable blade guard (6) in reverse
order.
Before using the saw again, check that the safety
devices are in good working order.
Important: Every time that you change the saw
blade, check to see that it spins freely in the
groove of the turntable in both perpendicular and
45° angle settings.
7.10 Storage compartment for spare saw blade
(Fig. 13)
The saw is equipped with a storage compartment
(33) for a spare saw blade.
To open the storage compartment, pull the locking
knob (34) on the rear of the saw while pulling the
storage compartment out at the same time.
7.11 Laser function (Fig. 12)
You can switch the laser ON and OFF with the
switch (a).
The laser (35) directs a beam onto the work-
piece.
Extremely precise cuts can be made using the
laser function.
8. Maintenance
Keep the machine’s air vents unclogged and
clean at all times.
Remove dust and dirt regularly from the machine.
Cleaning is best done with compressed air or a
rag.
Re-lubricate all moving parts in regular intervals.
Never use caustic agents to clean plastic parts.
9. Ordering replacement parts
Please quote the following data when ordering
replacement parts:
Type of machine
Article number of the machine
Identification number of the machine
Replacement part number of the part required
For our latest prices and information please go to
www.isc-gmbh.info