605901
17
Zoom out
Zoom in
Previous page
1/76
Next page
GB
- 17 -
Important!
The equipment and packaging material are
not toys. Do not let children play with plastic
bags, foils or small parts. There is a danger of
swallowing or su ocating!
Submersible pump
Original operating instructions
Safety instructions
3. Proper use
The equipment you have purchased is designed
to pump water with a maximum temperature of
35 °C. This equipment must never be used for
other liquids, especially engine fuels, cleaning
agents and other chemically-based products!
Before you use the pump, clarify any possible
special conditions which need to be ful lled for
the installation! For example, additional safety
measures may be needed if damage to property
could result from a power failure, soiling or a de-
fective gasket.
Examples of such safety measures: Pumps run-
ning in parallel on a separately protected power
circuit, moisture sensors for switching o the
pumps, and similar safety arrangements.
Be sure to consult a professional plumber if you
have any doubt.
The equipment can be used wherever you want to
move water, e.g. in the house, in the garden, and
for many other applications. It must not be used to
operate swimming pools!
If you want to use the equipment in bodies of wa-
ter with a natural, muddy bottom, place the equip-
ment in a slightly elevated position, e.g. on bricks.
The equipment is not designed for continuous
operation, e.g. as a circulating pump in a pond. In
this case the equipment’s anticipated life will be
greatly shortened because the equipment was
not designed for continuous loading.
The equipment is to be used only for its prescri-
bed purpose. Any other use is deemed to be a
case of misuse. The user / operator and not the
manufacturer will be liable for any damage or inju-
ries of any kind caused as a result of this.
Please note that our equipment has not been de-
signed for use in commercial, trade or industrial
applications. Our warranty will be voided if the
machine is used in commercial, trade or industrial
businesses or for equivalent purposes.
4. Technical data
Mains connection ...........................230V ~ 50 Hz
Power rating .............................................. 270 W
Max. pumping rate .................................6,800 l/h
Max. delivery head ..................................... 5.5 m
Max. immersion depth ................................... 5 m
Max. water temperature ............................. 35 °C
Hose connection ............ ca. 47, 8 mm (G11/2)IG
Max. size of foreign bodies: .....................Ø 5 mm
Switching point height: ON ....max. approx. 50 cm
Switching point height: OFF .....min. approx. 5 cm
Protection type ..............................................IPX8
5. Before starting the equipment
5.1 Installation
The equipment can be installed either:
Stationary with rigid tubing
or
Stationary with a flexible hose line
Note:
The maximum pumping rate is possible only with
the largest possible line diameter; if smaller hoses
or tubes are connected, the pumping rate will be
reduced. If the universal hose connection (Fig. 1/
Item 2) is used, it should be shortened (as shown
in Fig. 3) to the connection actually used in order
not to reduce the pumping rate unnecessarily.
Flexible hoses must be fastened to the universal
hose connection with a hose clip (not included in
the scope of supply).
Note!
When installing, never hang the equipment by the
discharge line or by the power cable. The equip-
ment must be hung up with the provided carry
handle or it must rest on the bottom of the shaft.
To ensure that the equipment works properly, the
bottom of the shaft always must be free of sludge
and other accumulations of dirt. If the water level
is too low, the sludge in the shaft can quickly dry
out and hinder the equipment from starting. It is
necessary therefore to check the equipment regu-
larly (carry out trial start-ups).
Anl_GH_SP_2768_SPK1.indb 17Anl_GH_SP_2768_SPK1.indb 17 26.09.12 09:0526.09.12 09:05
17


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Einhell GH-SP 2768 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Einhell GH-SP 2768 in the language / languages: English, Swedish as an attachment in your email.

The manual is 1,04 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Einhell GH-SP 2768

Einhell GH-SP 2768 User Manual - German, Dutch, French, Italian, Portuguese, Spanish - 68 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info