605860
15
Zoom out
Zoom in
Previous page
1/92
Next page
GB
- 15 -
machine is used in commercial, trade or industrial
businesses or for equivalent purposes.
4. Technical data
Mains connection: .......................... 230 V ~ 50 Hz
Power consumption: ................................... 900 W
Pumping rate without non-return valve: ....4100 l/h
Pumping rate with non-return valve: ......3800 l/h
Delivery head max. ...................................... 48 m
Delivery pressure max. ...........0.48 MPa (4.8 bar)
Suction height max. ....................................... 8 m
Pressure
connection: .approx. 33.3 mm (R1 female thread)
Suction
connection: ..approx. 33.3 mm (R1 female thread)
Water temperature max. ............................... 35°C
Tank capacity: .................................................20 l
Cut-in pressure approx.: ..........0.15 MPa (1.5 bar)
Cut-out pressure approx.: ............0.3 MPa (3 bar)
Protection type: .............................................IPX4
5. Before starting the equipment
Before you connect the equipment to the mains
supply make sure that the data on the rating plate
are identical to the mains data.
As a basic principle, we recommend the use of
a preliminary filter and a suction set with suction
hose, intake cage and non-return valve, in order
to prevent long priming periods and unnecessary
damage to the pump as a result of stones and
solid foreign bodies.
5.1 Connecting the intake line
Fasten the suction hose (at least approx. 19
mm (¾“) plastic hose with spiral reinforce-
ment) to the suction connection approx. 33.3
mm (R1 female thread) of the equipment eit-
her directly or via a threaded nipple.
The suction hose used should be equipped
with an intake valve. If the intake valve cannot
be used, a non-return valve should be ins-
talled in the intake line.
Position the intake line so that it rises from
the water withdrawal point to the equipment.
Avoid positioning the intake line higher than
the pump, as this would delay the escape of
air bubbles from the intake line and impede
the priming process.
Install the intake and discharge lines in such
a way that they do not exert any mechanical
pressure on the equipment.
The intake valve should be low enough in the
water to ensure that if the water level falls, the
unit will not run dry.
A leaking intake line will draw in air and there-
fore not draw in any water.
Prevent the intake of foreign bodies (sand,
etc.). If necessary, install a coarse filter for
this purpose.
5.2 Connecting the discharge line
The discharge line (min. 19 mm (¾“)) must
be connected to the 33.3 mm (R1IG) female
thread discharge line connector of the equip-
ment either directly or with the aid of a threa-
ded nipple.
With the right couplings it is also possible, of
course, to use a 13 mm (½ “) delivery hose.
The smaller delivery hose results in a lower
delivery rate.
During the priming operation, fully open any
shut-off mechanisms (spray nozzles, valves,
etc.) in the pressure line so that the air can
escape without obstruction.
5.3 Electrical connections
Connect the appliance to a 230 V ~ 50 Hz
socket-outlet with earthing contact. Minimum
fuse 10 ampere.
A built-in thermostat protects the motor from
overloading and blocking. The pump is swit-
ched off automatically by the thermostat if
overheating occurs and is switched on again
automatically after cooling.
6. Operation
Install the equipment on a solid and level
surface.
Remove the ventilation screw (8).
Unscrew the coarse filter screw (7) using the
supplied wrench (11) and remove the coarse
filter (9) together with the non-return valve
(10) as shown in Figure 2. Now you can fill the
pump housing with water via the coarse filter
screw (7). Filling the intake line accelerates
the intake process.
Assemble in reverse order.
Open the discharge line.
Connect the mains cable.
Anl_GE_WW_9041_E_SPK1.indb 15Anl_GE_WW_9041_E_SPK1.indb 15 26.06.14 12:5826.06.14 12:58
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Einhell GE-WW 9041 E at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Einhell GE-WW 9041 E in the language / languages: English, Danish, Swedish, Norwegian as an attachment in your email.

The manual is 1,1 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Einhell GE-WW 9041 E

Einhell GE-WW 9041 E User Manual - German, Dutch, French, Italian, Portuguese, Spanish - 60 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info