Using the cable clips supplied (Fig. 7), attach
the power cable to the tubes of the push bars
so that it is possible to open and shut the
ejector flap (Fig. 8/Item 10).
Please ensure that the ejector ap can be opened
and closed easily!
Adjusting the scari er depth (see Fig. 9)
The scari er depth is adjusted at both front
wheels via the adjustment mechanism. For this,
pull out the adjusting screw and turn the wheel to
the left or right into one of the available positions
(0/I/II/III).
The scari er depth must always be identically set
on both sides!
0 = drive/transport position
I = scari er depth 3 mm
II = scari er depth 7 mm
III = scari er depth 9 mm
Electrical connection
The equipment can be connected to any normal
socket with 230V AC. It is only acceptable to con-
nect it to a shockproof socket with a 16A circuit
breaker. Furthermore, a residual-current-operated
protective device with max. 30 mA should be con-
nected upstream.
Power cable
Please only use power cables that are not dama-
ged. The total length of the power cable should
not exceed 50 meters; going beyond this distance
will reduce the power output of the electric motor.
The power cable must have a cross-section of 3 x
1.5 mm2. The insulating sheath of scari er power
cables is frequently damaged.
Some of the causes for this are:
Cracking from running over the cable
Pinching when the power cable is dragging
under doors and pulled through windows
Cracking due to old age of the insulation
Kinking by improperly fastening or guiding the
power cable
The power cables must, at the very minimum, be
of type HO5RN-F and 3-stranded. The cable type
must be printed somewhere on the power cable.
Only purchase power cables that are marked as
such! Plugs and socket couplers for the power
cables must be made from rubber and be splash-
proof. There is a limit to how long power cables
can be. Longer power cables require larger con-
ductor cross-sections. Power cables and connec-
ting lines must be regularly checked for damage.
Ensure that the lines are de-energized before
checking them. Completely unwind the power
cable. Also check power cable entry points, plugs
and socket couplers for kinks.
6. Operation
Connect the machine’s power supply cable to the
plug (Fig. 10/Item 1) and secure the power cable
with the stress-relief clip (Fig 10/Item 2).
To prevent accidental start-up of the equipment,
the push-bar (Fig. 11 / Item 5) is equipped with
a safety lock-o (Fig. 11 / Item 2) which must be
pressed before the lever switch (Fig. 11 / Item 1)
can be pressed. If the lever switch is released, the
equipment switches o .
Repeat this process several times so that you are
sure that the machine functions properly. Before
you perform any repair or maintenance work on
the machine, ensure that the cutting unit is not ro-
tating and that the power supply is disconnected.
Important! Never open the ejector ap when the
motor is running. A rotating cutting unit can cause
injuries.
Always fasten the ejector ap carefully. The ap
ips back to the “Closed” position by the tension
springs!
Always ensure that a safe distance (provided
by the long handles) is maintained between the
user and the housing. Be especially careful when
scarifying and changing direction on slopes and
inclines. Maintain a solid footing and wear sturdy,
non-slip footwear and long trousers. Always sca-
rify along the incline (not up and down).
For safety reasons, the scari er may not be used
to scarify inclines whose gradient exceeds 15
degrees.
Use special caution when backing up and pulling
the scari er (tripping hazard)!
Tips for proper working
It is recommended that you overlap scarifying
paths a little.
Try to scarify in straight lines for a nice, clean look.
Insodoing, the aeration swaths should always
overlap each other by a few centimeters in order
to avoid bare strips.
Anl_GC_ES_1231_SPK1.indb 17Anl_GC_ES_1231_SPK1.indb 17 28.08.14 11:1628.08.14 11:16
17


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Einhell GC-ES 1231 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Einhell GC-ES 1231 in the language / languages: English, Danish, Swedish, Norwegian as an attachment in your email.

The manual is 1,57 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Einhell GC-ES 1231

Einhell GC-ES 1231 User Manual - German, Dutch, French, Italian - 44 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info