9
the guarantee period.
IMPORTANT
The equipment and packaging material are not
toys. Do not let children play with plastic bags,
foils or small parts. There is a danger of
swallowing or suffocating!
n Deep well pump
n Switchbox
n Securing cable
n Original operating instructions
3. Proper use
The equipment you have purchased is designed to
pump water with a maximum temperature of 35 °C.
This equipment must never be used for other liquids,
especially engine fuels, cleaning agents and other
chemically-based products!
The equipment is to be used only for its prescribed
purpose. Any other use is deemed to be a case of
misuse. The user / operator and not the
manufacturer will be liable for any damage or injuries
of any kind caused as a result of this.
Please note that our equipment has not been
designed for use in commercial, trade or industrial
applications. Our warranty will be voided if the
machine is used in commercial, trade or industrial
businesses or for equivalent purposes.
4. Technical data
Power supply 230V ~ 50Hz
Power rating 1300 Watt
Delivery rate max.. 5.000 l/h
Delivery height max 65 m
Immersion depth max. 20 m
Water temperature max. 35°C
Hose connection 47,8 mm (G11/2) IG
Max. particle size clear water
Power cable 2 m
Pump cable 23 m
5. Before putting the equipment into
operation
5.1 Installation
The equipment can be installed either:
n Stationary with rigid tubing
or
n Stationary with a flexible hose line
n Connect the pressure hose or pipe to the
pressure
connector (3) using a suitable connector.
n Fasten the securing cable (10) to the suspension
eyelet (Figure 3/Item A).
5.2 Mains connection
The equipment you have purchased comes with an
earthing-pin plug. The equipment is designed for
connection to a socket outlet with earthing contact for
230 V ~ 50 Hz. Make sure that the socket-outlet is
sufficiently fused (at least 6 A) and in good working
order. Insert the power plug in the socket-outlet and
the equipment is ready for operation.
Important!
To rule out danger, this work must be left strictly to a
specialist electrician or Customer Service.
6. Operation
You can put the equipment into operation after you
have thoroughly read the installation and operating
instructions. Pay attention to the following points:
Please note
The switchbox (Figure 2/Item 5) may only be
installed outside the well.
1. Lower the pump into the well or shaft using the
securing cable.
2. Ensure that the pump is completely submersed
in the
water.
3. Connect the mains plug on the switchbox to the
socket.
4. The mains indicator (Figure 2/Item 7) will be lit.
5. Press the On/Off switch (Figure 2/Item 8) to start
the pump. The operating indicator (6) will be lit.
Please note
If the pump suffers an overload the overload switch
(Figure 2/Item 9) will trip.
Push the switch in again after you have allowed the
unit to cool.
Anleitung_GC_DW_1300_N_SPK1__ 26.06.13 09:55 Seite 9
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Einhell GC-DW 1300 N at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Einhell GC-DW 1300 N in the language / languages: English, Danish, Swedish, Norwegian as an attachment in your email.

The manual is 0,95 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Einhell GC-DW 1300 N

Einhell GC-DW 1300 N User Manual - German, Dutch, French, Italian, Portuguese, Spanish - 40 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info