GB
11
CAUTION!
Read all safety regulations and instructions.
Any errors made in following the safety regulations
and instructions may result in an electric shock, fire
and/or serious injury.
Keep all safety regulations and instructions in a
safe place for future use.
2. Layout and items supplied (Fig. 1-3)
1. Carry handle
2. Tank cover with ventilation
3. Petrol cock
4. Starter cable
5. Motor cover
6. Spark plug cover
7. ON/OFF switch
8. Earthing connection
9. Economy switch
10. 1x 230V~ socket
11. Oil warning indicator
3. Proper use
The equipment is designed for appliances which
operate at 230 V ~. Be sure to observe the
restrictions in the safety instructions.
The machine is to be used only for its prescribed
purpose. Any other use is deemed to be a case of
misuse. The user / operator and not the
manufacturer will be liable for any damage or injuries
of any kind caused as a result of this.
Please note that our equipment has not been
designed for use in commercial, trade or industrial
applications. Our warranty will be voided if the
machine is used in commercial, trade or industrial
businesses or for equivalent purposes.
4. Technical data
Generator sychronised operation
Protection type: IP23
Continuous rated power P
rated
(S1): 650 W
Maximum power P
max
(S2 15 min) (230 V): 720 W
Rated voltage U
rated
: 1 x 230V~
Rated current I
rated
: 2.8 A (230 V)
Frequency F
rated
: 50 Hz
Drive engine design: 2-stroke, air-cooled
Displacement: 63 cm³
Max. power: 1.5 kW / 2 hp
Fuel: mixture 1:50
Tank capacity: 2.7 l
Consumption at 2/3 load: approx. 0.73 l/h
Weight: 18.7 kg
Sound pressure level L
pA
: 73 dB(A)
Sound power level L
WA
: 92 dB (A)
Spark plug: F5TC
Operating mode S1 (continuous operation)
The machine can be continuously operated with the
quoted power output.
Operating mode S2 (temporary operation)
The machine may be temporarily operated with the
quoted power output (15 min). Afterwards the
machine must be stopped for a while to prevent it
from overheating (15 min).
5. Before putting the machine into
operation
Remove the packaging material and check that all
items have been supplied. Place the generator on a
firm, flat surface near the consumer and ensure
proper ventilation.
5.1 Electrical safety:
앬 Electric supply cables and connected equipment
must be in perfect condition.
앬 The generator is to be operated only with
equipment whose voltage specifications conform
with the generator's output voltage.
앬 Never connect the generator to the power supply
(socket-outlet).
앬 Keep the cable length to the consumer as short
as possible.
5.2 Environmental protection
앬 Dispose of soiled maintenance material and
operating materials at the appropriate collection
point.
앬 Recycle packaging material, metal and plastics.
5.3 Connecting to earth
The housing is allowed to be connected to earth in
order to discharge static electricity. To do this,
connect one end of a cable to the earth connection