4. Technical data
Power supply: .................................... 230 ~ 50 Hz
Motor rating in kW: .......................................... 1.1
Operating mode .......................... S3 25% 10 min
Compressor speed in rpm: ........................... 3550
Operating pressure in bar: ................................. 8
Pressure vessel volume in litre: .......................... 6
Theoretical intake rate in l/min.: ...................... 185
Sound power level L
WA
in dB: ............................ 97
K
WA
uncertainty .............................................2 dB
Sound pressure level L
pA
in dB: ........................ 75
K
pA
uncertainty .............................................2 dB
Protection type: ............................................ IP 20
Machine weight in kg: ......................................... 9
Noise
The noise emission values were measured in ac-
cordance with EN ISO 3744.
5. Before starting the equipment
Before you connect the equipment to the mains
supply make sure that the data on the rating plate
are identical to the mains data.
Examine the machine for signs of transit da-
mage. Report any damage immediately to the
company which delivered the compressor.
The compressor should be set up near the
working consumer.
Avoid long air lines and long supply lines (ex-
tensions).
Make sure the intake air is dry and dust-free.
Do not set up the compressor in damp or wet
rooms.
The compressor may only be used in suitable
rooms (with good ventilation and an ambient
temperature from +5°C to +40°C). There must
be no dust, acids, vapors, explosive gases or
inflammable gases in the room.
The compressor is designed to be used in dry
rooms. It is prohibited to use the compressor
in areas where work is conducted with spray-
ed water.
6. Assembly and starting
Important!
You must fully assemble the appliance before
using it for the rst time.
6.1 Voltage
Before you use the machine, make sure that the
mains voltage complies with the speci cations on
the rating plate. Long supply cables, extensions,
cable reels etc. cause a drop in voltage and can
impede motor start-up. In the case of low tempe-
ratures below +5°C, motor start-up is jeopardized
as a result of sti ness.
6.2 On/O switch (8)
To switch on the equipment set the On/O switch
(8) to position 1.
Move the On/O switch (8) to position 0 to switch
o the equipment.
6.3 Adjusting the pressure: (Fig. 1)
You can adjust the pressure on the pressure
gauge (6) using the pressure regulator (7).
The set pressure can be taken from the quick-
lock coupling (5).
6.4 Setting the pressure switch
The pressure switch is set at the factory.
Switch-on pressure 6 bar
Switch-o pressure 8 bar
7. Replacing the power cable
If the power cable for this equipment is damaged,
it must be replaced by the manufacturer or its
after-sales service or similarly trained personnel
to avoid danger.
Anl_BT_AC_190_6_OF_SPK7.indb 15Anl_BT_AC_190_6_OF_SPK7.indb 15 19.04.12 08:2819.04.12 08:28
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Einhell BT-AC 190-6 OF at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Einhell BT-AC 190-6 OF in the language / languages: English, German, Dutch, French, Italian, Swedish, Finnish as an attachment in your email.

The manual is 1,13 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info