3. Items supplied
Open the packaging and take out the equipment
with care.
Remove the packaging material and any
packaging and/or transportation braces (if
available).
Check to see if all items are supplied.
Inspect the equipment and accessories for
transport damage.
If possible, please keep the packaging until the
end of the guarantee period.
IMPORTANT
The equipment and packaging material are not
toys. Do not let children play with plastic bags,
foils or small parts. There is a danger of
swallowing or suffocating!
Original operating instructions
4. Proper use
Applications
Irrigation and watering of green areas, vegetable
beds and gardens.
Operation of lawn sprinklers.
Drawing of water (with pre-filter) from ponds,
streams, rain barrels, rainwater cisterns and
wells.
Supplying water to the house.
Transport media:
For the pumping of clear water (fresh water),
rainwater or light suds/service water.
The maximum temperature of the fluid must not
exceed +35°C if the equipment is operated
permanently.
Do not use the equipment to pump inflammable,
gassing or explosive fluids.
The pumping of aggressive liquids (acids, alkalis,
silo seepage etc.) as well as liquids with abrasive
substances (sand) must likewise be avoided.
The equipment is to be used only for its prescribed
purpose. Any other use is deemed to be a case of
misuse. The user / operator and not the
manufacturer will be liable for any damage or injuries
of any kind caused as a result of this.
Please note that our equipment has not been
designed for use in commercial, trade or industrial
applications. Our warranty will be voided if the
machine is used in commercial, trade or industrial
businesses or for equivalent purposes.
5. Technical data
Mains connection 230V ~ 50 Hz
Power rating 1100 W
Max. pumping rate 4000 l/h
Max. delivery head 43 m
Max. delivery pressure 4.3 bar
Max. suction height 8 m
Pressure and suction connector 33,3 mm (R1IG)
Max. water temperature 35 °C
Tank capacity 20 l
Cut-in pressure approx. 0.15 MPa (1.5 bar)
Cut-out pressure approx. 0.3 MPa (3 bar)
6. Before putting the equipment into
operation
6.1 Connecting the intake line
As a basic principle, we recommend the use of a
preliminary filter and a suction set with suction
hose, suction strainer and non-return valve, in
order to prevent long priming periods and
unnecessary damage to the pump as a result of
stones and solid foreign bodies.
The intake hose or pipe should have a minimum
diameter of 25 mm (1”); a diameter of 32 mm
(11/4”) is recommended for suction heights
exceeding 5 m.
Connect the intake valve (foot valve) with intake
cage to the intake line.
Position the intake line so that it rises from the
water withdrawal point to the equipment. Avoid
positioning the suction pipe higher than the
pump, as this would delay the escape of air
bubbles from the suction pipe and impede the
priming process.
Install the intake and discharge lines in such a
way that they do not exert any mechanical
pressure on the equipment.
The intake valve should be low enough in the
water to ensure that if the water level falls, the
equipment will not run dry.
A leaking intake line will draw in air and therefore
not draw in any water.
6.2 Connecting the discharge line
The discharge line (min. 19 mm (3/4”)) must be
connected to the 33.3 mm (R1IG) female thread
discharge line connector of the equipment either
directly or with the aid of a threaded nipple.
GB
10