11
designed for use in commercial, trade or industrial
applications. Our warranty will be voided if the
machine is used in commercial, trade or industrial
businesses or for equivalent purposes.
4. Technical data
Mains connection 230V ~ 50 Hz
Power rating 550 W
Max. pumping rate 11,000 l/h
Max. delivery head 8,5 m
Max. immersion depth 8 m
Max. water temperature 35 °C
Hose connection 1 1/2“ female thread
Max. size of foreign bodies: Ø 5 mm
Switching point height: ON max. approx. 14 cm
Switching point height: OFF min. approx. 6 cm
Min. suction height: 5 mm
5. Before putting the equipment into
operation
5.1 Installation
The equipment can be installed either:
n Stationary with rigid tubing
or
n Stationary with a flexible hose line
Note:
The maximum pumping rate is possible only with the
largest possible line diameter; if smaller hoses or
tubes are connected, the pumping rate will be
reduced. If the universal hose connection (Fig. 1/Item
4) is used, it should be shortened (as shown in Fig. 6)
to the connection actually used in order not to reduce
the pumping rate unnecessarily. Flexible hoses must
be fastened to the universal hose connection with a
hose clip (not included in the scope of supply).
Note!
When installing, never hang the equipment by the
discharge line or by the power cable. The equipment
must be hung up with the provided carry handle or it
must rest on the bottom of the shaft. To ensure that
the equipment works properly, the bottom of the shaft
always must be free of sludge and other
accumulations of dirt. If the water level is too low, the
sludge in the shaft can quickly dry out and hinder the
equipment from starting. It is necessary therefore to
check the equipment regularly (carry out trial start-
ups).
Note:
The pump shaft should measure at least
40 x 40 x 50 cm so that the floating switch can move
freely.
5.2 Mains connection
The equipment you have purchased comes with an
earthing-pin plug. The equipment is designed for
connection to a socket outlet with earthing contact for
230 V ~ 50 Hz. Make sure that the socket-outlet is
sufficiently fused (at least 6 A) and in good working
order. Insert the power plug in the socket-outlet and
the equipment is ready for operation.
Important!
To rule out danger, this work must be left strictly to a
specialist electrician or Customer Service.
6. Operation
You can put the equipment into operation after you
have thoroughly read the installation and operating
instructions. Pay attention to the following points:
n Make sure that the equipment is set up securely.
n Check that the discharge line is fitted correctly.
n Make sure that the electrical connection is 230 V
~ 50 Hz.
n Check that the electrical socket-outlet is in good
working order.
n Make sure that no moisture or water can ever
reach the power connection.
n Make sure that the equipment does not run dry.
Function of the integrated floating switch
Automatic mode:
The selector switch (A) must be in the lower position
during automatic mode (Fig. 2). This activates the
integrated floating switch. The activation height is
approximately 14 cm. The pump switches off again at
approximately 6 cm.
Manual mode/shallow water:
The selector switch (A) must be in the upper position
to operate manually or in shallow water (Fig. 3). This
bridges the integrated floating switch so that the
equipment runs continuously. In manual mode water
can be sucked up until a level of 5 mm remains.
Anleitung_BG_SP_550_IF_SPK1__ 31.07.13 13:11 Seite 11
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Einhell BG-SP 550 IF at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Einhell BG-SP 550 IF in the language / languages: English as an attachment in your email.

The manual is 1,31 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Einhell BG-SP 550 IF

Einhell BG-SP 550 IF User Manual - German, Dutch, French, Italian, Portuguese, Spanish - 40 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info