overloading and blocking. The pump is switched
off automatically by the thermostat if overheating
occurs and is switched on again automatically
after cooling.
6. Operation
Install the equipment on a solid and level
surface.
Fill the pump housing with water via the water
filler screw (4). Filling the intake line accelerates
the intake process.
Open the discharge line.
Connect the mains cable. The intake process
starts automatically; water can be suctioned in
for up to 5 minutes (maximum suction height).
If the pump is removed again after use, it must
always be refilled with water whenever it is
connected up and used again.
7. Replacing the power cable
If the power cable for this equipment is damaged, it
must be replaced by the manufacturer or its after-
sales service or similarly trained personnel to avoid
danger.
8. Cleaning, maintenance and
ordering of spare parts
The equipment is almost completely maintenance
free. In order to ensure a long service life, however,
we recommend that you regularly check and care for
the product.
Important!
The equipment must be disconnected from the
power supply (pull the power plug) prior to
performing any maintenance.
8.1 Servicing
If the equipment becomes clogged, connect the
discharge line to the water line and disconnect
the suction hose. Open the water line. Switch on
the equipment several times for approx.
two seconds. This should resolve the majority of
clog-related problems.
Replacing the mains cable: Important:
Disconnect the equipment from the power
supply! A defective mains cable may only be
replaced by a qualified electrician.
There are no parts inside the equipment which
require additional maintenance.
8.2 Storage
If the pump is not going to be used for a long
time or has to be removed for the winter months,
rinse it out with water, empty it completely and
allow it to dry.
The equipment must be completely drained
before it is subjected to frost.
After long stoppages, make sure the rotor turns
correctly by briefly switching the pump on and
off.
8.3 Ordering replacement parts:
Please quote the following data when ordering
replacement parts:
Type of machine
Article number of the machine
Identification number of the machine
Replacement part number of the part required
For our latest prices and information please go to
www.isc-gmbh.info
9. Disposal and recycling
The unit is supplied in packaging to prevent its being
damaged in transit. This packaging is raw material
and can therefore be reused or can be returned to
the raw material system.
The unit and its accessories are made of various
types of material, such as metal and plastic.
Defective components must be disposed of as
special waste. Ask your dealer or your local council.
10. Storage
Store the equipment and accessories out of children’s
reach in a dark and dry place at above freezing
temperature. The ideal storage temperature is
between 5 and 30 °C. Store the electric tool in its
original packaging.
11
GB
Anleitung_BG_GP_1140_N_SPK1:_ 26.01.2012 7:19 Uhr Seite 11
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Einhell BG-GP 1140 N at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Einhell BG-GP 1140 N in the language / languages: English, Danish, Swedish, Norwegian as an attachment in your email.

The manual is 1,06 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Einhell BG-GP 1140 N

Einhell BG-GP 1140 N User Manual - German, Dutch, French, Italian, Portuguese, Spanish - 44 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info