Threaded socket suction and pressure joints pump head safety lock sealing ring preliminary
filter pad preliminary filter lid carbon filter pad fine filter pad filter media containers with filter
material slot multi-function lever filter canister rubber feet pump chamber impeller ball
with ball cage pump chamber cover 2 x union nuts 2 x shut-off taps outlet elbow intake pipe
with intake strainer suction holders.
First stick the 4 rubber feet to the bottom of the filter canister. The shut-off taps are then screwed onto the suction and
pressure joints of the filter which can be rotated in the required direction of the hose by means of the threaded
sockets and are marked with the stickers IN/OUT (Fig. B).
Then fix the outlet elbow to the aquarium by means of the suction holders. Join the intake pipe with the intake strainer
and attach them to the inside of the tank by means of the suction holders (Fig. C). Cut the hoses to the required
lengths and push them onto the intake pipe and outlet elbow for at least 1 cm. Make sure the hoses do not sag.
Connect the intake pipe to the suction joint “IN” of the filter, and the outlet elbow to the pressure joint “OUT(Fig. D).
Secure hoses at both connections by tightening the union nuts in the direction of the pipe.
Note: All hose connections must be checked at regular intervals for correct fitting.
The external filter already contains the necessary standard filter material made of special filter pads, a preliminary
filter with filter foam, a carbon filter pad and a fine filter pad. Rinse the filter material in the basket und running
water until the water runs off clear. When you have finished installing the hose, the device is completely ready for
operation.
Suction function: Now open both shut-off taps on the hose connections (Fig. E) and slowly move down the multi-
function lever until it is flush with the safety lock (Fig. F), lever position . Water is hereby sucked out of the aquar-
ium and the overflow is established, so that the filter canister fills automatically.
As soon as the water begins to flow into the filter canister, slowly move the multi-function lever back
to its vertical operating position until it locks noticeably into place (Fig. G), lever position . Once the system is com-
pletely filled, the filter is put into operation via the mains connection. WARNING: If the system is operated in lever posi-
tion , mechanical and biological filtration cannot be guaranteed.
Opening:
IMPORTANT. First close the shut-off tap on the suction side “IN(Fig. H), and afterwards the tap on the pressure side
“OUT(Fig. I) before disconnecting the mains plug (Fig. J). Loosen both taps by turning the threaded sockets to
separate the hose assembly from the filter.
WARNING: If the taps are not separated from the pump head the filter cannot be opened.
Now slowly move the multi-function lever into its horizontal position and then release the safety lock by apply-
ing strong pressure (Fig. L) so that the lever can be pushed over until it is touching the filter canister (Fig. M), lever
position . The pump head is thereby automatically pulled out of its seal and can be taken off.
A - D Installation
E - G Initial operation
H - M Opening and closing the filter
3
2
2
1
2
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Eheim eccoPro 200 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Eheim eccoPro 200 in the language / languages: All languages as an attachment in your email.

The manual is 4,74 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info