70
Internal Server
Check/uncheck to enable/disable the access
point’s internal RADIUS server.
EAP Internal
Authentication
Select EAP internal authentication type from
the drop down menu.
EAP Certificate File
Format
Displays the EAP certificate file format:
PCK#12(*.pfx/*.p12)
EAP Certificate File
Click “Upload” to open a new window and
select the location of an EAP certificate file to
use. If no certificate file is uploaded, the
internal RADIUS server will use a self-made
certificate.
Shared Secret
Enter a shared secret/password for use
between the internal RADIUS server and
RADIUS client. The shared secret should be 1
99 characters in length. This should match the
“MAC-RADIUS” password used in IV-3-1-3-6 or
IV-3-2-3.
Session Timeout
Set a duration of session timeout in seconds
between 0 86400.
Termination Action
Select a termination-action attribute:
“Reauthentication” sends a RADIUS request to
the access point, “Not-Reathentication” sends
a default termination-action attribute to the
access point, “Not-Send” no
termination-action attribute is sent to the
access point.
73


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Edimax OAP1750 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Edimax OAP1750 in the language / languages: English as an attachment in your email.

The manual is 4,27 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Edimax OAP1750

Edimax OAP1750 Quick start guide - Dutch - 25 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info