ENGLISH
INSTALLATION
Natural convection circulation Natural convection circulation
The hot air produced by the fireplace is released into The hot air produced by the fireplace is released into
the rooms to be heated by the nozzles connected to the rooms to be heated by the nozzles connected to
the holes on the cover of the hood with aluminium the holes on the cover of the hood with aluminium
pipes Ø 14 cm.It is essential to guarantee the return of pipes Ø 14 cm.It is essential to guarantee the return of
the air into the room where the fireplace is installed by the air into the room where the fireplace is installed by
means of grills at the base of the walls or gaps under means of grills at the base of the walls or gaps under
the doors.The diameter of the pipes must not be less the doors.The diameter of the pipes must not be less
than Ø 14 cm.than Ø 14 cm.
The line of the pipes must be as straight as possible. The line of the pipes must be as straight as possible.
The aluminium pipes can be hidden with coffer work or The aluminium pipes can be hidden with coffer work or
false beams or they can be built into the walls; in any false beams or they can be built into the walls; in any
case, they must be well insulated.case, they must be well insulated.
The channels must have a maximum length of 4÷5 m The channels must have a maximum length of 4÷5 m
each.each.
The said length must be decreased by 1.2 m for The said length must be decreased by 1.2 m for
every curve and for every nozzle consequent to the
consequent load loss.
The following kits are available to channel hot air.
Kit one/bis solo locale caminetto
Kit four/bis
Kit five/bis
Further details are provided in the assembly instructions
supplied with the kit itself.
Circulation with Kit Air DiffuserCirculation with Kit Air Diffuser
The Air Diffuser Kit carries hot air into the room where
the product is installed or into other rooms (depending
on the model), assisted by one or more fans.
It is adjusted with a remote control.
Edilkamin proposes two Air Diffuser Kit models:
ADJACENT Air Diffuser Kit
REMOTE Air Diffuser Kit
The difference is in the presence or 1 or 2 fans and the
relative aluminium pipes.
The kit can be combined with each of the following
Edilkamin vents:
Split, with lighting
Bent, with lighting
Origami
Sharp
The openings on the fireplace casing are initially The openings on the fireplace casing are initially
closed and must be opened by removing the pre-cut closed and must be opened by removing the pre-cut
membranes to enable the ambient air to pass through membranes to enable the ambient air to pass through
them.them.
The vents are not included in the Air Kit Diffuser and
you can choose the one of the models available and
described which best suits your needs at the retailer.
Kit Air Diffuser Remote- exKit 4 bis-ex
R2 unions
Vent
Alluminium
pipe
Vent
Fan
Control
unit
Aluminium pipe,
dia. 60 mm
Vent
Compensation vent
Compensation vent
Aluminium pipe,
dia. 100 mm
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Edilkamin Windo 2 - 75 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Edilkamin Windo 2 - 75 in the language / languages: English as an attachment in your email.

The manual is 2.93 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Edilkamin Windo 2 - 75

Edilkamin Windo 2 - 75 Usermanual and installation guide - German - 20 pages

Edilkamin Windo 2 - 75 Usermanual and installation guide - Dutch - 20 pages

Edilkamin Windo 2 - 75 Usermanual and installation guide - French, Italian - 40 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info