ENGLISH
INSTALLATION
Verify that the product works properly before
Verify that the product works properly before
applying the cladding.
applying the cladding.
In particular, check the following:
In particular, check the following:
Sliding elements
Sliding elements
Cabling
Cabling
Facings, gather hood and vents
Facings, gather hood and vents
Face the product only after having completed the
Face the product only after having completed the
following steps:
following steps:
connection of the product to the smoke outlet and
connection of the product to the smoke outlet and
air intake;
air intake;
inspection of the product when hot;
inspection of the product when hot;
check to verify whether the product is levelled.
check to verify whether the product is levelled.
The installer must implement all the installation good
The installer must implement all the installation good
practices and take all the necessary precautions
practices and take all the necessary precautions
against overheating and fire.
against overheating and fire.
In particular:
In particular:
if a plinth is constructed beneath the hearth level,
if a plinth is constructed beneath the hearth level,
it must include a suitable slot for the passage of
it must include a suitable slot for the passage of
recirculation air from the room;
recirculation air from the room;
wooden parts must be protected with fireproof
wooden parts must be protected with fireproof
panels, which must not be placed against one
panels, which must not be placed against one
another but spaced at least 1 cm apart to enable air
another but spaced at least 1 cm apart to enable air
to flow and prevent heat build-up. The gather hood
to flow and prevent heat build-up. The gather hood
can be made with fireproof panels, plasterboard
can be made with fireproof panels, plasterboard
or gypsum slabs; during construction, the hot air
or gypsum slabs; during construction, the hot air
ducting kit must be mounted as described above.
ducting kit must be mounted as described above.
The interior of the gather hood should be aerated
The interior of the gather hood should be aerated
by exploiting the flow of air coming from below (the
by exploiting the flow of air coming from below (the
space between the door and mantel) which convective
space between the door and mantel) which convective
currents will cause to exit from the grille on top,
currents will cause to exit from the grille on top,
thus allowing heat recovery and preventing undue
thus allowing heat recovery and preventing undue
overheating.
overheating.
In addition to that mentioned above, take into account
In addition to that mentioned above, take into account
the
the regulations in force in the relevant country
concerning
“insulation, finishes, facings and safety
“insulation, finishes, facings and safety
recommendations”.
recommendations”.
Vents
Vents
These must be strictly installed on the front: one
These must be strictly installed on the front: one
beneath and one above the fireplace’s opening. The
beneath and one above the fireplace’s opening. The
product is not supplied with.
product is not supplied with.
USE ONLY WITH REFRACTORIES
INSTALLED
27


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Edilkamin Windo 120 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Edilkamin Windo 120 in the language / languages: English as an attachment in your email.

The manual is 1.97 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Edilkamin Windo 120

Edilkamin Windo 120 Usermanual and installation guide - French - 40 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info