ENGLISH
INSTALLATION
INSTALLER
REMARKS ON INSTALLATION
REMARKS ON INSTALLATION
Please note that:
Please note that:
the installation must be carried out by qualified
the installation must be carried out by qualified
personnel;
personnel;
the appliance must be installed and used in
the appliance must be installed and used in
compliance with all local and national law and
compliance with all local and national law and
with European regulations; The Italian reference
with European regulations; The Italian reference
standard is UNI 10683. ; if the product is installed in
standard is UNI 10683. ; if the product is installed in
a condominium, the appliance must be approved
a condominium, the appliance must be approved
by the administrator;
by the administrator;
if the product is installed in public premises, check
if the product is installed in public premises, check
and follow the local regulations applicable to this
and follow the local regulations applicable to this
type of installation.
type of installation.
Below are a few general instructions which, however,
Below are a few general instructions which, however,
do not obviate the need to comply with local regulations
do not obviate the need to comply with local regulations
and do not imply any liability on the installer’s job.
and do not imply any liability on the installer’s job.
Checking the suitability of the room of
installation
The room must have a volume of at least 30 m3.
The floor must be able to bear the weight of the
product and its accessories* (see the note in the
paragraph on heat protection).
Level the appliance.
In Italy, pursuant to the UNI 10683 standard, the
appliance can also be installed in bedrooms or in
rooms which already include a product that takes
in combustion air from the same room, provided
that the air inlet is connected to the outside.
Do not install the product in rooms where there is
a risk of fire or explosion.
In Italy, verify the compatibility pursuant to the UNI
10683 and UNI 7129 standards in the presence of
gas-fired products.
Protection from heat and safety clearances
The surfaces of the building adjacent to the product
must be protected against overheating.
The insulation to be used will depend on the type of
surface in question.
The appliance must be installed in accordance with
the following safety instructions:
- minimum clearance of 15 cm at the sides and 10 cm
at the back from flammable materials;
- no flammable materials may be kept closer than 80
cm from the front of the appliance.
If the product is installed with a wooden wall or a wall
made of other flammable material, the flue must be
appropriately insulated.
If the product is installed on a flammable and/or
combustible floor, or on a floor incapable of bearing
its load*, we recommend placing a steel or glass plate
under the stove to distribute the load.
Contact the retailer for this type of optional feature.
Positioning the product
The product is designed to operate in all climate
conditions. In special circumstances, such as strong
wind, the safety devices may intervene to switch the
appliance off.
Contact the authorised Edilkamin Technical Assistance
Centre.
NOTE
The smoke outlet diameter does not match the chimney system diameter. The chimney system must
be sized in accordance with the national and local regulations.
In particular (this is not an exhaustive list), refer to the EN 13384, EN 1443, EN 1856, EN 1457
standards and to all local regulations.
17


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Edilkamin Vyda 2 H Up at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Edilkamin Vyda 2 H Up in the language / languages: English as an attachment in your email.

The manual is 5.68 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Edilkamin Vyda 2 H Up

Edilkamin Vyda 2 H Up Usermanual and installation guide - German - 76 pages

Edilkamin Vyda 2 H Up Usermanual and installation guide - French - 76 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info