810841
9
Zoom out
Zoom in
Previous page
1/40
Next page
9
ENGLISH
REMARKS ON INSTALLATION
REMARKS ON INSTALLATION
Note that:
Note that:
installation must be carried out by authorised
installation must be carried out by authorised
technical personnel;
technical personnel;
the appliance must be installed and operated in
the appliance must be installed and operated in
compliance with local and national law and European
compliance with local and national law and European
regulations. The Italian reference standard is UNI
regulations. The Italian reference standard is UNI
10683; in France one must follow the instructions in the
10683; in France one must follow the instructions in the
DTA (Document Technique d’Application Référence
DTA (Document Technique d’Application Référence
Avis Technique), www.cstb.fr
Avis Technique), www.cstb.fr
if installed in a condominium, the appliance must
if installed in a condominium, the appliance must
be approved by the administrator;
be approved by the administrator;
if installed in public premises, check and follow
if installed in public premises, check and follow
local regulations for this type of installation.
local regulations for this type of installation.
Here are a few general instructions, although these do
Here are a few general instructions, although these do
not obviate the need to comply with local regulations
not obviate the need to comply with local regulations
and do not affect the installer's liability for the
and do not affect the installer's liability for the
installation.
installation.
Remember that Vyda Air Tight is sealed, in other
Remember that Vyda Air Tight is sealed, in other
words, if it is installed correctly with the air inlet pipe
words, if it is installed correctly with the air inlet pipe
connected to the outside, it takes the majority of the
connected to the outside, it takes the majority of the
air from the outside. For different countries, check if
air from the outside. For different countries, check if
there are particular installation conditions allowed for
there are particular installation conditions allowed for
sealed stoves.
sealed stoves.
Checking the suitability of the installation
space
The room must have a volume of at least 30 m3
The floor must be able to bear the weight of the
product and its accessories* (see the note in the
paragraph on the heat protection)
Level the appliance
Pursuant to Standard 10683 rev. 2012 point 6.3, in
Italy you can also install the appliance in bedrooms
or in rooms which already include a product that
takes air from it for combustion, provided that the
air inlet is connected to the outside
Do not install the product in spaces where there is
a risk of fire or explosion
In Italy, check the compatibility pursuant to UNI
10683 and UNI 7129 in the presence of gas fired
products.
INSTALLATION
Protection from heat and safety clearances
The surfaces of the building adjacent to the product
must be protected against overheating.
The insulation to be used will depend on the type of
surface in question.
The appliance must be installed in accordance with
the following safety instructions:
- minimum clearance at the sides 15 cm and back of
10 cm from flammable materials
- no flammable materials may be kept closer to the
front of the appliance than 80 cm.
If connected to a wooden or otherwise flammable wall,
the flue must be appropriately insulated.
If installed on a flammable or combustible floor, or
which is not capable of bearing its load*, use steel or
glass plates under the stove to distribute the load.
Contact the retailer for this type of optional.
Positioning the product
The product is designed to operate in all climate
conditions. In special circumstances, such as strong
wind, the safety devices may intervene to switch the
appliance off.
Contact the authorised Edilkamin Technical Assistance
Centre.
INSTALLER
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Edilkamin Vyda 2 Air Tight C at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Edilkamin Vyda 2 Air Tight C in the language / languages: English as an attachment in your email.

The manual is 1.81 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Edilkamin Vyda 2 Air Tight C

Edilkamin Vyda 2 Air Tight C User Manual - German - 40 pages

Edilkamin Vyda 2 Air Tight C User Manual - Dutch - 40 pages

Edilkamin Vyda 2 Air Tight C User Manual - French, Italian - 76 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info