810868
13
Zoom out
Zoom in
Previous page
1/66
Next page
13
ENGLISH
• AVAILABLE VERSIONS
N natural convection
V forced ventilation
• CLEAN COMBUSTION SYSTEM: S.C.P.
Ensures high thermal efficiency and clean emissions
The system combines an innovative air distribution method of
primary combustion (A) and post-combustion (B)
the primary combustion air is fed into the firebox and is uniformly
distributed over the embers. This allows for the maximum possible
oxygenation and power necessary for optimal combustion;
air for post-combustion is taken in from the room through two
holes located at the base of the fireplace. This air heats up while travel-
ling through a channel designed specifically for this purpose at the back
of the firebox. The air is emitted into the roof of the firebox through a
well distributed drip system, in order to obtain the air/smoke mixture at
a high temperature.
• MANIGLIA ASPORTABILE PER APERTURA PORTELLONE
The handle of the hatch is not fixed to the same hatch but is inserted
when required.
The handle fits into the bottom of the door, by hooking it onto the pins.
The handle is only needed to lift or lower the hatch.
• BUILT-IN SYNOPTIC PANEL
for models with forced ventilation:
it allows you to manage and control the operating phases (ignition and
turning off) as well as adjust the fan speed from 1 to 9 in automatic or
manual mode.
• COMBUSTION AIR
New distribution system with:
A primary air brushing the surface of the hearth, controlled by
a recessed damper (use with protective tool)
B secondary air fed in directly from the top of the door thus
keeping the glass clean
C post-combustion air, pre-calibrated, it comes in from the
ceiling of the firebox
THE TECHNOLOGY
A
B
COMBUSTION DIAGRAM
post-combustion
air
primary air
A
B
primary combustion post-combustion
secondary air and
post-combustion
glass cleaning
C
A
B
B
B
A
C
primary air control lever
Closed
Open
secondary air inlet
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Edilkamin Titano Plus at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Edilkamin Titano Plus in the language / languages: English, Italian, Portuguese, Spanish as an attachment in your email.

The manual is 5.77 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info