DVICE IN THE EVENTOFPROBLEMS
H1) No Depression (this trips if the flow sensor detects insufficient combustion air flow)
Air flow may be insufficient because the door is open, the door does not close properly (e.g. bad seal), there is an air
intake or smoke extraction problem, or the combustion chamber is clogged.
Check:
- door closure;
- combustion air intake duct (clean, paying attention to the flow sensor components);
- clean the flow sensor with dry air (like that used for PC keyboards);
- stove location: it must not be installed against a wall;
- combustion chamber position and cleanliness (clean regularly according to the type of pellet);
- smoke duct (clean);
- installation (if it does not comply with regulations or the smoke outlet has more than 2-3 bends);
- flow sensor threshold (SF in the parameters) (only by the Dealer).
If you suspect the sensor is malfunctioning, carry out cold tests. If the conditions are changed (for example by opening
the door) and the value does not change, there is a sensor problem.
The no depression alarm may also occur during ignition, since the flow sensor starts monitoring 90 seconds after the
ignition cycle begins.
H2) Smoke expulsion motor failure (this trips if the smoke extraction speed sensor detects a fault)
- Check smoke extractor operation. (Performed solely by the Dealer)
- Check speed sensor connection. (Performed solely by the Dealer)
- Make sure the smoke duct is clean
- Check the earth connection (Performed solely by the Dealer)
SF(H3) Flame stop (this trips if the thermocouple detects a smoke temperature lower than the value set, which it
interprets as the absence of flames)
There may be no flames because:
- there are no pellets;
- too many pellets have smothered the flames;
- the maximum temperature thermostat has tripped (this is very unusual since there would be an excessive smoke
temperature).
AF(H4) No start (this trips if no flames appear and the start-up temperature is not reached within a maximum of 15
minutes)
There are two distinct cases:
H5) Power failure stoppage
Check the electrical connection and for voltage drops (the block does not depend on the stove).
H6) Thermocouple failure (this trips if the thermocouple fails or is disconnected) (only by the Dealer).
Check connection between the thermocouple and the circuit board.
Check operation with cold tests.
H7) Excessive smoke temperature (shutdown due to excessive smoke temperature)
Excessive smoke temperature may be caused by:
the type of pellet, smoke extraction fault, blocked duct, incorrect installation, or gearmotor "drift".
Err. 1 - Err. 2
The heating stove will not stop, but this message appears on the display. The buffer battery on the pcb must be replaced.
Contact the DEALER.
the flame does NOT appear Flames appear, but AFappears on the display afterAr
Check:
- combustion chamber position and
cleanliness;
- arrival of combustion air in the combustion
chamber;
- if the heating element is working;
- room temperature (if lower than 3°C use a
firelighter) and damp.
Try to light with a firelighter.
Check: (only by the Dealer)
- if the thermocouple is working;
- start-up temperature setting in the parameters.
ENGLISH
24
sk tecnica SEVEN multilingua_provvisoria cod 644310.qxp 27/04/2010 16.35 Pagina 25
24


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Edilkamin Seven at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Edilkamin Seven in the language / languages: English, German, Dutch, French, Italian, Spanish as an attachment in your email.

The manual is 6,68 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info