* The heatable room dimensions are calculated on the basis of pellets with a lhv of at least 4300 kcal/kg and home insulation
in compliance with Italian law 10/91, and subsequent changes together with an expected heat output of 35 Kcal/m³ per hour. It
is also important to consider the location of the stove in the room to be heated.
ELECTRICALSPECIFICATIONS
Power supply 230Vac +/- 10% 50 Hz
0/1 switch yes
Average power consumption 150 W
Power consumption during
ignition
400 W
Remote control frequency
(optional)
infrared
Protection on mains power
supply *
2A, 250 Vac 5x20
Fuse
Electronic circuit board
protection
2A, 250 Vac 5x20
Fuse
N.B.
1) Bear in mind that external devices may cause interference.
2) Caution: live parts. Servicing and/or inspections must be carried out by qualified staff.
(Before carrying out any maintenance, disconnect the device from the mains power supply)
SAFETY DEVICES
THERMOCOUPLE: on the smoke outlet.
It measures the smoke temperature.
It controls the ignition, operating and shutdown
stages according to the parameters set.
AIR FLOW SENSOR: on the intake duct. It trips
when the flow of combustion air is not correct,
therefore causing low pressure problems in the
smoke circuit.
SAFETYTHERMOSTAT:
It trips if the temperature inside the stove is too
high. It stops pellet loading, thus causing the stove
to go out.
THERMOCOUPLE
ROOM
SENSOR
FLOW
SENSOR
SMOKE EXTRACTION
MOTOR
SCREW FEEDER
MOTOR
230 V AC MAINS
50 Hz +/- 10%
VENTILATION
IGNITION
HEATING ELEMENT
SAFETY
THERMOSTAT
2A FUSE
ENGLISH
16
SMOKE SPEED
P/TEMP.
ADJUSTMENT
VENTILATION
ADJUSTMENT
SERIALPORT
The Dealer can install an optio-
nal on the AUX outlet (clean
contact on the pins) for control-
ling the process of switching on
and off (e.g. telephone remote, local thermostat), located
at the rear oh the stove. Can be connected via special
optional trestle (code 620550).
BACKUPBATTERY
Abackup battery is found on the control board (3-Volt CR
2032 battery). Its malfunction is indicated with the follo-
wing messages: (not considered a defect but due to nor-
mal wear-and-tear): ERR 1 - ERR 2. For more detailed
information, please contact the DEALER who has perfor-
med the first 1st ignition.
FUSE
* two fuses are inserted on
the socket behind the stove,
fitted with a switch one is
functional and the other is
spare.
*
*
pin 7
pin 6
BACKUP
BATTERY
HEATINGSPECIFICATIONS
Nominal power 7,0 kW
Efficiency nominal power 90 %
Emissions CO (13% O2) nominal power 100 ppm
Smoke mass nominal power 5,5 g/s
Reduced power 2,1 kW
Efficiency reduced power 92,3 %
Emissions CO (13% O2) reduced power 280 ppm
Smoke mass reduced power 2,9 g/s
Maximum overheated smoke 150 °C
Minimum draught 12 Pa
Time between refuellings (min/max) 8,5 / 25 hours
Fuel consumption (min/max) 0,6 / 1,7 kg/h
Hopper capacity 15 kg
Heatable room dimensions * 170
m
3
Weight including packaging 145 kg
Smoke duct diameter (Amale) 80 mm
Air intake duct diameter (B male) 40 mm
457 mm
77 mm
316 mm
369 mm
106 mm
Ø 40 mm
Ø 80 mm
B
A