ENGLISH
INTRODUCTION ON INSTALLATION
Remember that:
the product must be installed by qualified staff
who can issue a Declaration of Conformity
all the local and national laws and the European
Standards must be met for installation and use of
the product.
In the event of installation in apartment blocks, ask
the administrator’s opinion beforehand.
We give some general instructions below, however
these do not obviate the need to comply with local
regulations and do not affect the installer’s liability for
the installation.
INSTALLATION
CHIMNEY SYSTEM
(Smoke channel, chimney flue and chimney
stack)
This chapter is drafted according to the European
Standards EN 13384, EN 1443, EN 1856, EN 1457.
The installation technicians must take into consideration
these and any other local standards. The manual
should in no way be considered a replacement for the
laws in force.
The product must be connected to a suitable smoke
discharge that guarantees completely safe evacuation
of the smoke produced by combustion.
Before positioning the product, you need to check the
chimney flue is suitable.
SMOKE CHANNEL, CHIMNEY FLUE
The smoke channel (pipe that connects the smoke
outlet of the fireplace with the chimney flue inlet) and the
chimney flue must, along with other legal provisions:
• receive the discharge for a single product (multiple
product discharges are not permitted together)
• have a mainly vertical development
• no section should have a reserve slope
• have an inner section preferably circular and
however with a ratio between sides lower than 1.5
• complete the roof with the appropriate chimney
stack: direct discharge is forbidden on walls or
towards closed spaces, even if outdoors
• be created with materials with a fire reaction class
A1 pursuant to UNI EN 13501 or similar national
standard
• be appropriately certified, with an appropriate
fireplace plate, if metal
• keep the initial section
The hot air can circulate naturally
(natural convection) or with the aid of a
ventilation system (AIR DIFFUSER KIT)
to be purchased separately and applied
BEFORE completing the installation
process.
Contact your retailer for any further
information.
Checking the suitability of the installation
premises
The volume of the room must be over 40 m3
Installation is not permitted in bedrooms,
bathrooms or premises with other products that
take in air for combustion of the same premises
or in premises with an explosive atmosphere. Any
extractor fans, if working in the same environment
or space in which the product is installed, can
cause draft problems.
In Italy, check compatibility pursuant to UNI 10683
and UNI 7129 in the presence of gas products.
The floor must be able to support the weight of the
product and the accessories.
Protection from heat and safe distances
All the surfaces of the building adjacent to the pro-
duct must be protected against heating.The insulation
measurements to implement depend on the type of
surface present.
The product must be installed in accordance with the
following safety instructions:
- minimum distance of 20 cm from flammable mate-
rials along the sides and back.
- no flammable materials may be kept within 80 cm
from the front of the appliance.
Electricity lines
There must be no electricity lines in the
walls or ceiling of the fireplace installation
area.
16


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Edilkamin Screen Evo 80-2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Edilkamin Screen Evo 80-2 in the language / languages: English as an attachment in your email.

The manual is 6.22 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Edilkamin Screen Evo 80-2

Edilkamin Screen Evo 80-2 Usermanual and installation guide - French, Italian - 52 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info