810729
18
Zoom out
Zoom in
Previous page
1/32
Next page
- 46 -
ENGLISH
INSTALLATION
g. 23
X
g. 24 Y
NOTES ON FITTING THE COVERING
In using a prefabricated Edilkamin covering, to identify the
exact position of PELLKAMIN is important to verify the mo-
del of the covering to be used.
Positioning differs according to the model chosen (see as-
sembly instructions given in the packaging of each covering).
Always check that installation is perfectly vertical and horizon-
tal.
COVERINGS, COUNTER-HOODS AND THEIR
VENTILATION
Before installing the covering, check that all connections, com-
mands and moving parts are perfectly functional.
Check this with the insert on and working for a few hours. Do
so prior to tting the covering in order to intervene as necessa-
ry.
Finishing works, such as construction of the counter-hood,
covering assembly, pilaster preparation, painting, etc.,
should be carried out once the nal test has been passed.
Edilkamin will therefore not be held liable for any charges
deriving from both demolition and reconstruction works,
even where consequent to replacement of any faulty insert
parts.
Rather, at least 1 cm. (approx.) space must be left to allow
air to ow, thereby preventing heat from accumulating.
The counter-hood can be created from reproof plaster-
board panels or plaster sheets. When creating this, the air
circulation grill must be included, as previously specied.
- THE MANTEL CAN BE CONSTRUCTED WITH FIRE
RESISTANT PANELS IN PLASTERBOARD OR
GYPSUM BOARD.
- AERATION GRILLES FOR PREVENTING ANY
EXCESS TEMPERATURE INSIDE MUST BE PROVI-
DED FOR DURING CONSTRUCTION (g. 23).
During the construction phase of the covering it is funda-
mental to ensure that the combustion air is restored
to prevent pressure phenomena in the room where the
replace is installed (refer to the Chapter regarding the
external air inlet on page 40)
In addition to the above, always consider the indications
given by paragraphs 4.4 and 4.7 of standard UNI 10683
“insulation, nishes, coverings and safety recommenda-
tions”.
N.B.: IMPORTANT FOR INSTALLATION CONDITIONS
* Provide two aeration grilles (area larger than 100 cm2), the
rst one under the insert and the second positioned at least 50
cm above the insert or anyway communicating with the internal
compartment where the insert is positioned.
These grilles prevent the accumulation of heat inside, which is
then used to help heat the room of installation.
* Internal mantel
ventilation grilled
External
intake * Recycled air
intake inspection
METAL PROFILE FINISHING PLATE (X) FOR
MOUNTING OF “FRAME” COVERINGS
(supplied)
After removing the lower grille, you can mount, on the lower
base of the structure, the “angular” metal nishing prole (X
– for “frame” coverings or plasterboard) in place of the metal
prole plate (Y) previously mounted (see Fig. 24).
18


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Edilkamin Pellkamin 10 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Edilkamin Pellkamin 10 in the language / languages: English as an attachment in your email.

The manual is 4.57 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Edilkamin Pellkamin 10

Edilkamin Pellkamin 10 Usermanual and installation guide - German - 28 pages

Edilkamin Pellkamin 10 Usermanual and installation guide - Dutch - 28 pages

Edilkamin Pellkamin 10 Usermanual and installation guide - French, Italian - 56 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info