Manufacturer Edilkamin S.p.A.
Trademak Edilkamin
Model Identifier Nara2 Plus up
Description Mechanically space heater fired by wood pellets
Indirect heating functionality no
Direct heat output (space heat output) 9,2 kW
CPR harmonised standard EN 14785
Notified Body Acteco srl (Via Amman 41 ,33084 Cordenons-PN-Italy) NB1880
Fuel Preferred fuel
(unique)
PM OGC CO NOx PM OGC CO NOx
Compressed wood with moisture content < 12 % yes 15 11 113 139 10 10 159 128
Observe the specific precautions for installation, assembly and maintenance indicated in the manual accompanying the product
Up to 1/1/2022 From 01/01/2022
ɻs [%] 84,0 ɻs [%] 84,0
EEI [%] 124 EEI [%] 124
Energy Efficiency Class A+ A+
Calculations according to the council commission regulation (EU) 2015/1186 and 2015/1185
BLF =1,45
F5 not of relevance
Heat output Useful efficiency (NCV as received)
Item Symbol Value Unit Item Symbol Value Unit
Nominal heat output Pnom 9,2 kW ɻth,nom 88,5 %
Minimum heat output
(indicative)
Pmin 3,8 kW ɻth,min 88,4 %
Auxiliary electricity consumption
Item Symbol Value Unit NO
At nominal heat output elmax 0,178 kW NO
At minimum heat
out
ut
elmin 0,018 kW NO
In standby mode elsb 0,002 kW NO
NO
F(4)
1,4 % CC =2,5
yes
F (2) 7,0 % up to 2022
F (2) 7,0 % from 2022
NO
NO
with distance control option yes
F (3) 1,0 % up to 2022
F (3) 1,0 % from 2022
Contact details
Name and address of the manufacturer www.edilkamin.com
EDILKAMIN S.p.A. mail@edilkamin.com
Via Mascagni 7 Legal Representative
20045 Lainate (MI) – ITALY Paolo Gusella
Other control options (multiple selections possible)
room temperature control, with presence detection
room temperature control, with open window
detection
single stage heat output, no room temperature
control
two or more manual stages, no room temperature
control
with mechanic thermostat room temperature
control
with electronic room temperature control
with electronic room temperature control plus day
timer
with electronic room temperature control plus
week timer
TECHNICAL DOCUMENTATION FOR LOCAL SPACE HEATERS ACCORDING TO COMMISSION REGULATION (EU) 2015/1185 AND 2015/1186
Type of heat output/room temperature control (select one)
Space heating emissions at nominal heat output Space heating emissions at minimum heat
output
Only required if correction factors F(2) or F(3) are applied.
(*) PM = particulate matter, OGCs = organic gaseous compounds, CO = carbon monoxide, NOx = nitrogen oxides
mg/m3 at 13%O2 mg/m3 at 13%O2
Energy Efficiency
Class
Characteristics when operating with the preferred fuel
Useful efficiency at nominal
heat output
Useful efficiency at
minimum heat output
(indicative)