6
ENGLISH
TECHNICAL CHARACTERISTICS per EN 14785
Nominal power Reduced power
Available power 9,2 3,8 kW
Efficiency 88,5 88,4 %
CO emissions at 13% O20,010 0,010 %
Fumes temperature 188 131 °C
Fuel consumption* 2,1 0,9 kg/h
Tank capacity 24 kg
Draw 11 10 Pa
Autonomy 11 27 hours
Heatable volume ** 240 m3
Fumes outlet diameter (male) 80 mm
Air intake diameter (male) 40 mm
Weight including packaging 130 kg
Energy efficiency class according to UE 2015-
1186 regulation (Class A++/G) A+
TECHNICAL DATA FOR RATING THE FLUE
which must in any case satisfy the requirements of this sheet and the installation instructions for the product
Nominal power Reduced power
Fumes temperature at outlet 226 157 °C
Minimum draw 0,01 Pa
Fumes flow rate 6,5 4,2 g/s
ELECTRICAL SPECIFICATIONS
Power 230 Vac +/- 10% 50 Hz
Mean absorbed Nominal power 178 W
Mean absorbed Reduced power 18 W
Mean absorbed Stand by power 3 W
Power absorption during ignition 300 W
Remote control frequency (provided) 2,4 GHz
Protection Fuse 4 AT, 250 Vac 5x20
TECHNICAL CHARACTERISTICS
USER/INSTALLER
*A calorific value of 4.8 kW/Kg has been used to calculate consumption.
** The heatable volume is calculated based on the assumption of a heating demand of 33 Kcal/m³ hour.
*** Accessories are available to channel hot air.
The product can be used safety even with a higher depression.
An higher depression can cause decrease in efficiency.
NOTE: smoke outlet Ø not equal to the chimney system one, to be adjusted accordingly
EDILKAMIN s.p.a. reserves the right to modify the product without notification in the
interests of improvement.