PROBLEM CAUSE SOLUTIONS
synoptic panel is off no mains voltage
check that the power cable is
connected; check the fuse (on power
socket, page 26)
remote control (optional) not working
too far from stove move closer to the stove
remote control battery flat
check the battery and if necessary,
replace it
output air is not hot too much soot in exchanger
clean the hearth exchanger using the
specific rods (see page 40)
the flame does not appear (remember
that it should appear 5 minutes after
pressing the 0/1 key)
the feed screw has not been filled
fill the feed screw
(see paragraph regarding ignition,
page 32)
does not ignite
accumulation of unburnt residue in
the combustion chamber
clean combustion chamber
Error rtc-dr displayed on the
synoptic panel
the backup battery inside the
control board is flat
replace the backup battery
the ignition/shutdown phase does not
start at the preset time
incorrect settings:
current time
program activation
activation of the daily program
verify in accordance with guidelines
TROUBLESHOOTING ADVICE (for the DEALER)
1) Verification of air flow (intervenes if the flow sensor detects insufficient combustion air flow).
Shuts down due to insufficient circulation in the combustion chamber
Flow may be insufficient if the door is open or does not close properly (e.g. flawed seal), if there is a problem with the
air inlet or smoke extraction, if the combustion chamber is blocked or the flow sensor is dirty (clean with dry air).
Check flow sensor limits (within the parameters indicated for the DEALER). The depression alarm may also be
signalled during ignition.
2) Verification of the extractor (intervenes if the revolution sensor of the smoke extractor detects an anomaly)
Shuts down due to an anomaly in the revolution sensor of the smoke expulsion motor
- check smoke extractor functionality (connection of the revolution sensor)
- check smoke channel for dirt
- check electrical system (earth)
3) Stop Flame (intervenes if the thermocouple detects a smoke temperature that is lower than that which is set, thereby
interpreting it as a failure) shuts down due to a drop in the smoke temperature
The flame may not go on for the following reasons:
- lack of pellets
- too many pellets have suffocated the flame
- the maximum thermostat has intervened (this is rare but occurs in an excessive smoke temperature)
POSSIBLE TROUBLESHOOTING
ENGLISH
38
38


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Edilkamin Melody Line AIDA at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Edilkamin Melody Line AIDA in the language / languages: English, French, Italian as an attachment in your email.

The manual is 5,1 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Edilkamin Melody Line AIDA

Edilkamin Melody Line AIDA User Manual - German, Dutch, Spanish - 67 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info