TROUBLESHOOTING RECOMMENDATIONS
TECHNICAL SPECIFICATIONS
The electronic system includes the following probes and sensors
ID DESCRIPTION TYPE
S6 High boiler probe: it detects the water temperature in the upper part of
the boiler
NTC 10KΩ
S7 Boiler probe: it measures the temperature of the water on leaving the boiler NTC 10KΩ
S1 Fume probe: it detects the temperature of the fumes on leaving Type K Ther-
mocouple
INAT3 Manual reset limit thermostat 90°C
INBT2 Door contact Microswitch Clean Contacts N.C.
INBT3 Room Thermostat Clean Contacts N.C.
λLambda Probe LS 17025
IT IS ABSOLUTELY FORBIDDEN TO USE OTHER TYPES OF PROBES OR
SENSORS
The following motors and drives are connected to the electronic board of the boiler
ID DESCRIPTION VOLTAGE POWER
OUT1 Suction fan 230 V 120 W
OUT7 System pump 230 V 250 W Max.
OUT8 Accumulation tank pump 230 V 250 W Max.
M1 Primary air valve 24V AC 3 W
M2 Secondary air valve 24V AC 3 W
PLEASE NOTE: Any tampering or modication to the electronic control unit will void
the warranty.
36


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Edilkamin LAGUNA W Up at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Edilkamin LAGUNA W Up in the language / languages: English as an attachment in your email.

The manual is 4.2 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Edilkamin LAGUNA W Up

Edilkamin LAGUNA W Up Usermanual and installation guide - French, Italian - 92 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info