ENGLISH
INSTALLATION
HYDRAULIC CONNECTIONS
Located with the LAGUNA2 P are:
a pressure gauge;
a closed expansion vessel
If the expansion tank is built into the boiler,
this does NOT ensure proper protection of
the water in the entire system from ther-
mal expansion.
Therefore, installers should assess wheth-
er an additional expansion tank is needed,
depending on the type of system.
ALL OTHER HYDRAULIC COMPONENTS MAY BE
INSTALLED WITHIN THE BOILER BY PURCHASING
A KIT FROM EDILKAMIN OR IF PREPARED BY THE
INSTALLER.
The hydraulic connection depends on the type of
system.
However, there are some “general rules”:
The hydraulic system must operate at a pressure
between 1 and 1.5-2 bars at running temperature
(hot) in a closed vessel circuit.
N.B.: DO NOT, for example, install the boiler to
replace a heat storage stove installed as an open
vessel, without adapting the expansion system to
closed vessel.
The installation of a puffer (accumulation tank) is
recommended, but is not essential. The advantage
of a puffer is that it releases the boiler from “sudden”
requests from the system and allows integration
with other heat sources. The system consumes
less fuel while efficiency is increased. Edilkamin
suggest a puffer.
The return temperature of water to the boiler must
be higher than 50-55° C to prevent the forming of
condensation.
Where the need exists to heat low-temperature
radiant panels, a puffer (accumulation tank)
should be installed as recommended by the panel
manufacturer.
The material used in the circuit must be suitable to
withstand any overheating.
The installer must determine, on the basis of the type
of water and system if water conditioners are required. In
Italy, refer to UNI 8065-1989 (water treatment in heating
systems for civil use).
Direct plumbing to radiators prevents proper operation,
owing to the small diameter of their pipes.
PRESSURE GAUGE
placed on the boiler enables you to read the water
pressure in the boiler.
Edilkamin offers four internal kits (optional)
- KIT R
for installing a single heat source without domestic hot
water production
- KIT R2
For combined installation with a second boiler without
domestic hot water production with system separator.
- KIT RW
For installing a single heat source with instantaneous
domestic hot water production.
- KIT RW2
For combined installation with a second boiler with
domestic hot water production and system separator.
20


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Edilkamin LAGUNA 2 P at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Edilkamin LAGUNA 2 P in the language / languages: English as an attachment in your email.

The manual is 9.68 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Edilkamin LAGUNA 2 P

Edilkamin LAGUNA 2 P Usermanual and installation guide - German - 37 pages

Edilkamin LAGUNA 2 P Usermanual and installation guide - Dutch - 40 pages

Edilkamin LAGUNA 2 P Usermanual and installation guide - French, Italian - 76 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info