ENGLISH
INSTALLATION
upper terminal block (low voltage)
lower terminal block (high voltage)
POLES POSSIBLE CONNECTION NOTES
1/2
Gas Boiler consent. Dry contact outlet. Applicable to all configurations.
Standard open contact.
A relay must be installed in order to provide consent to
the gas boiler if the Laguna2 P is not connected to the
power supply.
3/4
Home Automation Input. This is an input which
receives all home automation contacts
A telephone dialler, for example
5/6
ntc sensor/local thermostat the local thermostat is supplied as standard
7/8
ntc sensor/puffer or boiler thermostat one common pole
9/10
AUX sensor, ntc analogue input for example, for a second puffer or boiler
11/12 Domestic hot water inlet for boiler thermostat. Set configuration 2
POLES POSSIBLE CONNECTION NOTES
1/2/3 Thre way valve (Neutral and Line)
4/5/6 External circulator electrical connection (Earth,
Neutral, Line,)
ELECTRICAL TERMINAL CONNECTIONS
On the back (with the protective cover removed), there
is a bracket with two terminals and five cable glands.
One terminal block (12 poles) is low voltage, the other
(6 poles ) is high voltage).
Below you can see the connection
16


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Edilkamin LAGUNA 2 P at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Edilkamin LAGUNA 2 P in the language / languages: English as an attachment in your email.

The manual is 9.68 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Edilkamin LAGUNA 2 P

Edilkamin LAGUNA 2 P Usermanual and installation guide - German - 37 pages

Edilkamin LAGUNA 2 P Usermanual and installation guide - Dutch - 40 pages

Edilkamin LAGUNA 2 P Usermanual and installation guide - French, Italian - 76 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info