499667
46
Zoom out
Zoom in
Previous page
1/70
Next page
ENGLISH
46
AN EXAMPLE OF A HYDRAULIC SYSTEM FOR A BOILER-STOVEWITH HOT SANITARY WATER PRODUCTION USINGKIT 6
Kit 6 is designed to facilitate the work carried out by the installers. In fact, it consists of all the necessary components for the product to be
properly installed.
NB: insulating mats must be applied so that the components of the kit are well protected from the heat radiation emitted by the boiler-
stoves.
1
2
3
4
5
6
7
C
D
F
11
12
13
B
8
9
10
A
E
KIT 6
SELECTOR FUNCTIONS
Selector: OFF Everything is switched off
Selector: MAN Driven Circulator
Valve is set
Selector: AUTO Circulator is set
Valve is set
Alarm selection No acoustic signal in the
OFF position
KIT 6 code 280600
1" Ball Valve
Thermal Relief Valve (72940)
Pressure Relief Valve (284220)
Circulator (219660)
Fittings with 1" Check Valve (284180)
¾" Male 3-way Solenoid Valve (283690)
Fittings
20-plate Heat Exchanger for hot sanitary water
production (284300)
Temperature Relief Valve Nozzle
Closed Expansion Tank (283680)
Flow Switch (220830)
½" Thermometer Well + Sensor (175960)
Electronic Regulator (220780)
3/8" Automatic Relief Valve (284150)
1/4" Manual Relief Valve (284170)
Manometer (269590)
Boiler-stoves Return
System Return
Boiler-stoves Return
Cold Sanitary Water
Pressure Relief Valve
Hot Sanitary Water
Temperature Relief Valve
14
15
16
G
NB: essential safety connections
safety valve connection
ACS:
AF:
AL:
C:
EV:
NA:
NC:
F:
GR:
Ja:
Jm:
MAN:
MI:
P:
RA:
RE:
RI:
S:
SC:
ST:
V:
Vec:
VR:
VSP:
VST:
Hot Sanitary Water
Cold Water
Water Mains Supply
Filling/Top-Up Section
3-way Solenoid Valve
Normally Open
Normally Closed
Flow Switch
Filling unit
Automatic Relief Valve
Manual Relief Valve
Manometer
System Flow
Pump (circulator)
Radiators
Electronic Regulator
System Return
Drain
Plate Exchanger
Temperature Sensor
Ball Valve
Closed Expansion Tank
Check Valve
Pressurised Safety Valve
Thermal Relief Valve
ON
OFF
20 - 80° C
Circulator Setting
Fuse
Display
20 - 80° C
Valve Setting
Flow Switch
Attention: Connect the
normally closed contact
Power Supply
230 Vac
Circulator
3-way valve
Circulator enabled
Overheating alarm
3-way valve
Enable
Disable
Acoustic
Alarm
Sensor
(insert in the
appropriate well)
Componenti KIT 6
The sales codes are in brackets ( )
Electrical Connections
SYSTEM FOR A CLOSED TANKINSTALLATION
Collector
Regulator and manometer
(included in the kit)
20-plate heat
exchanger
sk KLIMA WARM multilingue_fra 30 04 2010.qxp 12/05/2010 11.32 Pagina 47
46


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Edilkamin KLIMA at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Edilkamin KLIMA in the language / languages: English, French, Italian as an attachment in your email.

The manual is 5,45 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Edilkamin KLIMA

Edilkamin KLIMA User Manual - German, Dutch, Spanish - 74 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info