42
Kit N3 is designed to facilitate the work carried out by the installers. In fact, it consists of all the necessary components for the product to
be properly installed.
NB: insulating mats must be applied so that the components of the kit are well-protected from the heat radiation emitted by the
boiler-stoves.
KIT N3 code 627690
Components KIT N3
CA: Wall Mounted Boiler
PR: Pump (circulator)
P1: Primary circuit pump
RE: Electronic regulator
TA: Room thermostat
VE: Expansion Tank
Ja: Air refief Valve
V: Intercept valve
VR: Retaining valve
ST: Temperature Sensor
F: Flow switch
Sc: Heat plate exchanger
EV: 3-way solenoid valve
RI: Heating system return
RA: Radiators
MI: Heating system flow
AF: Cold water
ACS: Hot sanitary water
S: Drain
SYSTEM FOR AN OPEN TANK INSTALLATION
AN EXAMPLE OF A HYDRAULIC SYSTEM FOR A THERMO FIREPLACEITH HOT SANITARY WATER PRODUCTION AND A WALL MOUNTED BOILER USING KIT N3
Heating system return G 3/4”
EDILKAMIN generator flow G 3/4”
EDILKAMIN generator return G 3/4”
Heating system flow G 3/4”
Cold sanitary water inlet G 1/2”
Hot water return to the sanitary system G 1/2”
Safety valve - temperature and pressure (90 °C - 3bar)
Flow Switch
Air relief valve G 3/8”
EDILKAMIN generator circuit circulator
3-way heat exchanger
Intercept valve G 1”
Electronic regulator with wiring
Appropriate aperture for the cable duct to pass through
Power cable
Cables for the heating system circulator
(phase, neutral, earth)
Temperature sensor
Room thermostat circuit
1
2
3
4
5
6
7
11
12
13
8
9
10
VE
AF
S
V
RE
RETE
ST
V
S
V
Tubo di carico Ø> 18 mm
Tubo di sicurezza Ø> 28 mm
V
CA
ACS
PR
F
ACS
AF
Ja
TA
P1
V
Vs
Sc
TCN
ELETTRICA
INT
VR
V
VR
RETE
IDRICA
VR
VR
MI
RA
RI
V
COLLETTORE
VR
V
V
V
V
V
Circuito collegabile al
termostato ambiente
(a discrezione del cliente)
Da collegare necessariamente
al circolatore dell’impianto
di riscaldamento
PR
1
2
3
4
5
6
7
8
9
10
11
9
9
12
13
1
2
3
5
4
6
7
14
15
16
17
Passacavi
18
14
15
16
17
18
KIT N3
Collector
Safety pipe Ø> 28mm
Inlet pipe Ø> 18mm
Electricity
Mains
Water
Mains
Cable duct
circuit connected to
the room thermostat
(implemented by the
client)
must be connected to the
heating system circulator
Electrical Connections
Room thermostat
Electricity
Mains
sensor
Sanitary-heating enabled setting
Primary circulator enabled setting
Enabled alarm
Flow sensor
Heating pump
Primary circuit pump
sk KLIMA WARM multilingue_fra 30 04 2010.qxp 12/05/2010 11.32 Pagina 43
42


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Edilkamin KLIMA at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Edilkamin KLIMA in the language / languages: English, French, Italian as an attachment in your email.

The manual is 5,45 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Edilkamin KLIMA

Edilkamin KLIMA User Manual - German, Dutch, Spanish - 74 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info