INSTALLATION
g. 1
g. 3
A
g. 4
B
D
C
HYDRAULIC KIT INSTALLATION
Caution:
Before implementing the hydraulic connections, always
disconnect the power supply.
Before installing the chosen HYDRAULIC KIT you must carry
outthefollowingsteps(seeg.1):
•Removetherearcasing(A)securedbyscrews.
•Removethemetalsidepanel(B)securedbyscrews.
At this point you can proceed with the installation of the
chosen hydraulic kit.
R KIT
Attach the delivery pipe (M) to the hydraulic kit using the 3/4"
seal supplied.
Connect the boiler delivery pipe to delivery pipe (M) on the
hydraulic kit, inserting the 3/4" seal supplied and screwing
themtogetherwithcare(g.2).
Connecttheexiblepipeoftheexpansionvesseltothe
V-ttingofthehydraulickit(seeFig.2)
Insert the two teeth (F) of the kit support into the two slots (G)
inside the boiler base.
Connectthemanometercapillarytotheappropriatettingon
thehydraulickitandfastenitwiththeclipprovided(seeg.8).
Insert the boiler return pipe into the O-ring and couple it to
the connection on the body of the circulator located on the kit,
securingitwiththespecialclip(g.2).
Use the screws provided to fasten the kit support to the rear of
theboiler(g.3).
N.B.: Complete the operation by tightening the elbows
connected to the kit, if required (delivery/return/H2O)
R2 KIT
To assemble the kit, proceed as above.
Afxthemetalsupporttotherearoftheboiler,usingscrews
(C-Fig.4).Thissupportstheplateexchangerandthe
protectivecasing(D-g.4).
Connectthetwoexiblepipessupplied,fromtheplate
exchanger,tothehydraulicdeliveryandreturnconnectionson
the previously installed hydraulic kit (see pages 25-26).
N.B.: Complete the operation by tightening the elbows
connected to the kit, if required (delivery/return/H2O)
screw
screw
delivery
return
g. 2
M
FF
GG
delivery
return
V
23


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Edilkamin Kit - R-RW-R2-RW2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Edilkamin Kit - R-RW-R2-RW2 in the language / languages: English, German, Dutch, Danish, French, Italian, Portuguese, Spanish as an attachment in your email.

The manual is 18.38 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info