ENGLISH
WATER CIRCUIT INSTALLATION
PLUMBING
Vyda H and Kira H are provided with a closed expansion
tank.
The built-in expansion tank does NOT ensure proper
protection of the water in the entire system from thermal
expansion.
Therefore, installers should assess whether an
additional expansion tank is needed, depending on the
type of system.
ALL OTHER HYDRAULIC COMPONENTS MAY
BE INSTALLED WITHIN THE BOILER STOVE BY
PURCHASING A KIT FROM EDILKAMIN OR IF
PREPARED BY THE INSTALLER.
Plumbing depends on the type of system.
However, there are some “general rules”:
The hydraulic system must operate at a pressure
between 1 and 1.5-2 bar at running temperature
(hot) in a closed vessel circuit.
DO NOT install the boiler stove as a replacement in
a system with an open expansion tank.
The presence of an accumulator (tank) is
recommended but not mandatory. Its advantage
is that it releases the boiler stove from “sudden”
requests from the system and can be integrated
with other heat sources. It reduces fuel
consumption and increases the efficiency of the
system. Edilkamin recommends an accumulator of
at least 20 l/kW.
The return temperature of water to the boiler
stove must be higher than 50-55° C to prevent the
formation of condensation.
An accumulator (tank) is needed to heat low-
temperature radiant panels and must be installed
according to the panel manufacturer's instructions.
The material used in the circuit must be suitable to
withstand overheating.
The installer must determine whether or not to use
conditioned products. In Italy, refer to UNI 8065
(Water treatment in heating systems for civil use).
Direct plumbing to radiators prevents proper
operation, owing to the small diameter of their pipes.
Edilkamin offers four internal kits (optional)
PIPE KIT
it consists of delivery and return pipes if the other
hydraulic components are installed externally (pump,
etc.).
R KIT (specific for Vyda H and Kira H)
for installations without the production of instant
domestic hot water.
R2 KIT (specific for Vyda H and Kira H)
For installations without the production of instant
domestic hot water with system separator.
RW KIT (specific for Vyda H 22 and Kira H 22)
For installations with the production of instant domestic
hot water. Recommended for 22 kW models only.
PRESSURE GAUGE
Kira H and Vyda H are provided with an electronic
reading system for water pressure. Therefore, there is
no analogue pressure gauge. Water pressure is shown
on the display, on the bottom left (*) as indicated in
the figure below. Edilkamin proposes an analogue
pressure gauge as optional.
VENT
During normal operations the vent
is automatic. During installation, the
technician must check the functionality of
the automatic vent and assess whether a
manual vent needs to be installed.
INSTALLER
check that the swivel nut (G) on
the two output pipes of the boiler
stove are closed
The product, without any kit, comes as shown in the
figure below.
G
(*)
Real size templates are available for technicians.
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Edilkamin Kira H at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Edilkamin Kira H in the language / languages: English as an attachment in your email.

The manual is 6.04 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Edilkamin Kira H

Edilkamin Kira H Usermanual and installation guide - German - 52 pages

Edilkamin Kira H Usermanual and installation guide - Dutch - 52 pages

Edilkamin Kira H Usermanual and installation guide - French, Italian - 104 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info