ENGLISH
ECODESIGN TECHNICAL DATA
USER/INSTALLER
Manufacturer Edilkamin S.p.A.
Trademak Edilkamin
Model Identifier Blade H 22 Kira H 22 Vyda H 22
Description Mechanically space heater fired by wood pellets
Indirect heating functionality si
Direct heat output (space heat output) 2,5 kW
Indirect heat output (space heat output) 20 kW
CPR harmonised standard EN 14785
Notified Body Kiwa Cermet Italia (San Vendemiamo, Treviso, Italy) NB 0476
Fuel Preferred fuel
(unique)
PM OGC CO NOx PM OGC CO NOx
Compressed wood with moisture content < 12 % yes 14 2 147 123 21 3 93 114
Observe the specific precautions for installation, assembly and maintenance indicated in the manual accompanying the product
Up to 1/1/2022 From 01/01/2022
ɻ
s
[%] 88,9 ɻ
s
[%] 81,9
EEI [%] 131 EEI [%] 124
Energy Efficiency Class A++ A+
Calculations according to the council commission regulation (EU) 2015/1186 and 2015/1185
BLF =1,45
F5 not of relevance
Heat output Useful efficiency (NCV as received)
Item Symbol Value Unit Item Symbol Value Unit
Nominal heat output P
nom
22,5 kW ɻ
th,nom
92,7 %
Minimum heat output
(indicative)
P
min
4,9 kW ɻ
th,min
95 %
Auxiliary electricity consumption
Item Symbol Value Unit NO
At nominal heat output el
max
0,080 kW NO
At minimum heat
out
p
ut
el
min
0,060 kW NO
In standby mode el
sb
0,004 kW NO
NO
F(4)
0,8 % CC =2,5
yes
F (2) 7,0 % up to 2022
F (2) 0,0 % from 2022
NO
NO
with distance control option yes
F (3) 1,0 % up to 2022
F (3) 0,0 % from 2022
Contact details
Name and address of the manufacturer www.edilkamin.com
EDILKAMIN S.p.A. mail@edilkamin.com
Via Mascagni 7 Legal Representative
20045 Lainate (MI) – ITALY Paolo Gusella
Other control options (multiple selections possible)
room temperature control, with presence detection
room temperature control, with open window
detection
single stage heat output, no room temperature
control
two or more manual stages, no room temperature
control
with mechanic thermostat room temperature
control
with electronic room temperature control
with electronic room temperature control plus day
timer
with electronic room temperature control plus week
timer
TECHNICAL DOCUMENTATION FOR LOCAL SPACE HEATERS ACCORDING TO COMMISSION REGULATION (EU) 2015/1185 AND 2015/1186
Type of heat output/room temperature control (select one)
Space heating emissions at nominal heat output Space heating emissions at minimum heat
output
Only required if correction factors F(2) or F(3) are applied.
(*) PM = particulate matter, OGCs = organic gaseous compounds, CO = carbon monoxide, NOx = nitrogen oxides
mg/m3 at 13%O2 mg/m3 at 13%O2
Energy Efficiency
Class
Characteristics when operating with the preferred fuel
Useful efficiency at nominal
heat output
Useful efficiency at minimum
heat output (indicative)
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Edilkamin Kira H - EKleaner at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Edilkamin Kira H - EKleaner in the language / languages: English as an attachment in your email.

The manual is 5.99 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Edilkamin Kira H - EKleaner

Edilkamin Kira H - EKleaner Usermanual and installation guide - German - 52 pages

Edilkamin Kira H - EKleaner Usermanual and installation guide - Dutch - 52 pages

Edilkamin Kira H - EKleaner Usermanual and installation guide - French, Italian - 104 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info