810914
60
Zoom out
Zoom in
Previous page
1/76
Next page
60
FRANÇAIS
Pour gérer les différents types d’installation, connecter les sondes à la borne de raccordement, en fonction des
besoins.
POUR INSTALLATEUR : INSTALLATION HYDRAULIQUE
INSTALLATEUR
Les configurations prédéfinies sont au nombre de 4, illustrées ci-dessous
BORNIER COMPLETE
15-16 SONDE BOUILLOIRE (optionnel NTC 10K) – THERMOSTAT BOUILLEUR (optionnel)
13-14 CONTACT DOMOTIQUE (en entrée)
11-12 SONDE AMBIANT (de serie) ou THERMOSTAT AMBIANT (optionnel)
9-10 SONDE PUFFER (optionnel NTC 10K) – THERMOSTAT PUFFER (optionnel)
7-8 DOUBLE SONDE PUFFER - CHAUDIERE (optionnel NTC 10K)
4-5-6 CONTACT AUX (en sortie,TA chaudiere aux ou valve trois voie COM-NC-NA)
1-2-3 ALIMENTATION POMPE SECONDAIRE (Terre / Neutre / Phase)
DOMOTIQUE CONTACT 13-14
Pour tous types de systèmes :
CHAUFFAGE - BOUILLOIRE - PUFFER - PUFF / TUB
il est possible de connecter une télécommande à contact propre (fermé sur demande, ouvert
pas sur demande).
Ce contact a la même fonction que le bouton marche/arrêt sur l’écran.
Après la fermeture du contact, cependant, le thermopoêle suivra son objectif défini par le
système sélectionné et les fonctions qui lui sont associées, comme cela se produit lorsque le
bouton d’alimentation sur l’écran est enfoncé.
60


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Edilkamin Kira 2 H Up at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Edilkamin Kira 2 H Up in the language / languages: French as an attachment in your email.

The manual is 6.02 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Edilkamin Kira 2 H Up

Edilkamin Kira 2 H Up Usermanual and installation guide - English - 68 pages

Edilkamin Kira 2 H Up Usermanual and installation guide - German - 76 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info